2008
DOI: 10.1016/j.aca.2008.05.032
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of dentifrice adulteration with diethylene glycol by means of ATR-FTIR spectroscopy and chemometrics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
10
0
7

Year Published

2009
2009
2019
2019

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 19 publications
(18 citation statements)
references
References 20 publications
1
10
0
7
Order By: Relevance
“…The presence of water and polyol molecules on the surface of the elaborated particles is also supported by the FT-IR study (Fig. 7) showing the bands corresponding to the bending and stretching vibrations of CH 2 of the polyol appearing, respectively, in the 1300-1650 and 2800-3000 cm À1 regions, the bands around 1650, 2325 and 2350 cm À1 corresponding to the bending mode of the OH groups of water and solvent and finally the broad bands around 3400 cm À1 corresponding to the stretching mode of the O-H groups [29,30].…”
Section: Thermal Analysissupporting
confidence: 58%
“…The presence of water and polyol molecules on the surface of the elaborated particles is also supported by the FT-IR study (Fig. 7) showing the bands corresponding to the bending and stretching vibrations of CH 2 of the polyol appearing, respectively, in the 1300-1650 and 2800-3000 cm À1 regions, the bands around 1650, 2325 and 2350 cm À1 corresponding to the bending mode of the OH groups of water and solvent and finally the broad bands around 3400 cm À1 corresponding to the stretching mode of the O-H groups [29,30].…”
Section: Thermal Analysissupporting
confidence: 58%
“…The FDA has recently taken steps to reduce the risks due to biomedical substances adulterated with the economically motivated adulteration. To get rid of this problem, the FDA has directed the manufacturers of finished products to assay and confirm that incoming glycerol should meet the specified limits () [1–3]. Therefore, before using glycerol for any human consumption, it is a prime and uttermost requirement to test its purity with reasonable accuracy.…”
Section: Introductionmentioning
confidence: 99%
“…to quantify alterants, [6] and for the simultaneous quantification of multiple products for in-line quality control in manufacture. [7] So if working models can be developed for pharmaceutical drugs, there is a good potential that models for illicit drugs can also be developed.…”
Section: Introductionmentioning
confidence: 99%