2022
DOI: 10.21037/qims-22-15
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of dynamic corneal nerve changes using static landmarks by in vivo large-area confocal microscopy—a longitudinal proof-of-concept study

Abstract: Background:The purpose of the present proof-of-concept study was to use large-area in vivo confocal laser scanning microscopy (CLSM) mosaics to determine the migration rates of nerve branching points in the human corneal subbasal nerve plexus (SNP).Methods: Three healthy individuals were examined roughly weekly over a total period of six weeks by large-area in vivo confocal microscopy of the central cornea. An in-house developed prototype system for guided eye movement with an acquisition time of 40 s was used… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 37 publications
0
2
0
Order By: Relevance
“…In this longitudinal study, care was taken to evaluate SNP parameters at each time point from the same regions within each patient's SNP mosaic. For the registration of longitudinal SNP mosaics, static landmarks of the cornea, such as Kobayashi structures [43,44] and nerve entry points, were used as previously described in [45]. The subsequent image processing and quantitative image analysis were performed by a dedicated algorithm using Mathematica (Version 11.3, Wolfram Research Inc., Champaign, IL, USA), as previously described [42].…”
Section: Assessment Of Anterior Corneal Segment Imaging and Quantitat...mentioning
confidence: 99%
See 1 more Smart Citation
“…In this longitudinal study, care was taken to evaluate SNP parameters at each time point from the same regions within each patient's SNP mosaic. For the registration of longitudinal SNP mosaics, static landmarks of the cornea, such as Kobayashi structures [43,44] and nerve entry points, were used as previously described in [45]. The subsequent image processing and quantitative image analysis were performed by a dedicated algorithm using Mathematica (Version 11.3, Wolfram Research Inc., Champaign, IL, USA), as previously described [42].…”
Section: Assessment Of Anterior Corneal Segment Imaging and Quantitat...mentioning
confidence: 99%
“…In this longitudinal study, care was taken to evaluate SNP parameters at each time point from the same regions within each patient's SNP mosaic. For the registration of longitudinal SNP mosaics, static landmarks of the cornea, such as Kobayashi structures [43,44] and nerve entry points, were used as previously described in [45].…”
Section: Assessment Of Anterior Corneal Segment Imaging and Quantitat...mentioning
confidence: 99%