Assessment of elemental fractionation and matrix effects during in situ Rb–Sr dating of phlogopite by LA-ICP-MS/MS: implications for the accuracy and precision of mineral ages

Abstract: Laser-ablation inductively-coupled plasma tandem mass-spectrometry (LA-ICP-MS/MS) allows for rapid and interference free analyses of Rb and Sr isotopes, permitting in-situ Rb–Sr dating of minerals. However, the general lack of matrix...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

2
99
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 59 publications
(101 citation statements)
references
References 47 publications
2
99
0
Order By: Relevance
“…This is approximately 4.4% younger than the published mean age of Mica-MG (519.4 ± 6.5 Ma; Hogmalm et al 2017). A discussion of the categorical differences and deviations between Mica-MG and MDC can be found in length within Redaa et al (2021). To summarise, the observed differences in elemental Rb/Sr fractionation between the nano-powder and natural mineral flakes of the same phlogopite are likely due to their different ablation properties (Redaa et al, 2021).…”
mentioning
confidence: 81%
See 3 more Smart Citations
“…This is approximately 4.4% younger than the published mean age of Mica-MG (519.4 ± 6.5 Ma; Hogmalm et al 2017). A discussion of the categorical differences and deviations between Mica-MG and MDC can be found in length within Redaa et al (2021). To summarise, the observed differences in elemental Rb/Sr fractionation between the nano-powder and natural mineral flakes of the same phlogopite are likely due to their different ablation properties (Redaa et al, 2021).…”
mentioning
confidence: 81%
“…Laser analyses on samples and standards were carried out at Adelaide Microscopy, University of Adelaide using a laser ablation (RESOlution-LR ArF 193nm excimer laser) inductively couple-mass spectrometer (Agilent 8900x ICP-MS/MS) with the analytical parameters and tuning conditions following (Redaa et al, 2021) summarised in Table 1.…”
mentioning
confidence: 99%
See 2 more Smart Citations
“…S3). Laser analyses on samples and standards were carried out at Adelaide Microscopy, University of Adelaide using a laser ablation (RESOlution-LR ArF 193nm excimer laser) inductively couple-mass spectrometer (Agilent 8900x ICP-MS/MS) with the analytical parameters and tuning conditions following (Redaa et al, 2021) summarised in Table 1.One spot analysis consisted of 20 seconds of gas background collected while the laser was not firing followed by 40 seconds of ablated signal. Strontium isotopes were measured in the oxidised molecule SrO.…”
mentioning
confidence: 99%