2020
DOI: 10.1507/endocrj.ej19-0488
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of factors that determine the mean absolute relative difference in flash glucose monitoring with reference to plasma glucose levels in Japanese subjects without diabetes

Abstract: The Abbott FreeStyle Libre flash glucose monitoring system (FGM) is a recently introduced, but widespread continuous glucose monitoring system. While its mean absolute relative difference (MARD) value indicating its accuracy is acceptable with reference to the self-monitoring of blood glucose (SMBG) levels, few reports have examined the MARD in sensor glucose values of FGM (FGM-SG) with reference to plasma glucose (PG) levels and the factors determining it. We performed oral glucose tolerance tests (OGTTs) in … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 22 publications
0
3
0
Order By: Relevance
“…The second source of the gap in laboratory and real‐life MARDs might be due to biologically‐relevant differences between these conditions 24 . In our study, we demonstrated that a number of factors might impair FSL accuracy 18 . First, we noted significantly worse MARD during daytime hours (9:00‐23:59—MARD: 12.8%) than at night (0:00‐8:59—MARD: 8.9%).…”
Section: Discussionmentioning
confidence: 62%
See 1 more Smart Citation
“…The second source of the gap in laboratory and real‐life MARDs might be due to biologically‐relevant differences between these conditions 24 . In our study, we demonstrated that a number of factors might impair FSL accuracy 18 . First, we noted significantly worse MARD during daytime hours (9:00‐23:59—MARD: 12.8%) than at night (0:00‐8:59—MARD: 8.9%).…”
Section: Discussionmentioning
confidence: 62%
“…During the 2019 camp five clinical factors were investigated as potentially disturbing FSL‐B accuracy 18 . We demonstrated that FSL‐B accuracy was decreased during daytime as opposed to nighttime (MARD 12.82% ± 11.38% vs 8.88% ± 9.01%, P < .0001), within 2‐3 hours after main meals as opposed to just before main meals (13.26% ± 11.96% vs 10.11% ± 9.66%, P < .0001), during prolonged physical activity vs everyday conditions (16.6% ± 18.02% vs 11.43% ± 9.74%, P < .0001), and in patients with adverse skin reactions (13.48% ± 12.89% vs 11.14% ± 10.49%, P = .0129).…”
Section: Resultsmentioning
confidence: 99%
“…Although most studies have shown that isCGM systems are within a safe clinical range [10][11][12] conclusive large-scale assessments of isCGM performance and the impact of the rate of change in glucose are currently lacking. Therefore, the aim of this pooled analysis was to assess isCGM (FreeStyle Libre 1; Abbott Diabetes Care, Alameda, California) performance and the rate of change in sensor glucose in a cohort of children, adolescents, and adults with type 1 diabetes.…”
Section: Introductionmentioning
confidence: 99%