2022
DOI: 10.1016/j.ejrad.2022.110185
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of hepatic steatosis based on virtual non-contrast computed tomography: Initial experiences with a photon counting scanner approved for clinical use

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
11
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
10

Relationship

4
6

Authors

Journals

citations
Cited by 24 publications
(19 citation statements)
references
References 38 publications
2
11
0
1
Order By: Relevance
“…Other studies tended to show larger discrepancies between VNC and TNC, 75 and VNC images from PCD-CT resulted in overestimation and underestimation of the true unenhanced attenuation of adrenal adenomas. 76 When investigating possible clinical applications, VNC images from PCD-CT were found to be reliable for the assessment of hepatic steatosis 77 and for emphysema quantification from contrast-enhanced lung scans. 78 The combination of high temporal and spatial resolution with spectral data acquisition enables novel applications for cardiovascular CT. For example, material decomposition into iodine and calcium can be used to remove the iodine from cCTAs, leaving only the calcium in the coronary arteries (PURE Calcium, Siemens Healthcare).…”
Section: Spectral Imaging Capabilitiesmentioning
confidence: 99%
“…Other studies tended to show larger discrepancies between VNC and TNC, 75 and VNC images from PCD-CT resulted in overestimation and underestimation of the true unenhanced attenuation of adrenal adenomas. 76 When investigating possible clinical applications, VNC images from PCD-CT were found to be reliable for the assessment of hepatic steatosis 77 and for emphysema quantification from contrast-enhanced lung scans. 78 The combination of high temporal and spatial resolution with spectral data acquisition enables novel applications for cardiovascular CT. For example, material decomposition into iodine and calcium can be used to remove the iodine from cCTAs, leaving only the calcium in the coronary arteries (PURE Calcium, Siemens Healthcare).…”
Section: Spectral Imaging Capabilitiesmentioning
confidence: 99%
“…Sartoretti et al provide further information on these novel QIR algorithms [ 18 ]. Both preclinical studies using PCCT prototypes and early studies with the first PCCT scanner that is approved for clinical use show promising results [ 15 , 16 , 19 , 20 , 21 ].…”
Section: Introductionmentioning
confidence: 99%
“…55 Single-energy and DECT have been shown to have good accuracy in fat quantification for higher fat fractions, and radiomics analysis can distinguish normal liver tissue from steatotic tissue. 56 Photon-counting CT has been shown to be accurate for index-based liver fat estimation from VNC images 57 but can also perform 3-material decomposition on all abdominal imaging and has the potential to improve opportunistic screening for hepatic steatosis (Fig. 4).…”
Section: Liver Fat Quantificationmentioning
confidence: 99%