2018
DOI: 10.1371/journal.pone.0193082
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of inhalation flow patterns of soft mist inhaler co-prescribed with dry powder inhaler using inspiratory flow meter for multi inhalation devices

Abstract: The patients’ inhalation flow pattern is one of the significant determinants for clinical performance of inhalation therapy. However, the development of inhalation flow meters for various inhalation devices has been unable to keep up with the increasing number of newly launched inhalation devices. In the present study, we developed simple attachment orifices for the inhalation flow pattern monitoring system, which are suitable for all commercial inhalers, and investigated the efficacy of the system on the clin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
21
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 28 publications
(21 citation statements)
references
References 34 publications
0
21
0
Order By: Relevance
“…This device has similar steps to Turbuhaler ® , and in a study with 165 patients with asthma and COPD, both devices had more incorrect applications compared with Diskus ® or Ellipta ® (28). Breezhaler ® requires an inspiratory flow greater than 50 L/min for the powder dispersion (56). This is higher than the inspiratory flow rated needed to action the Synchrobreathe device.…”
Section: Breezhaler ®mentioning
confidence: 96%
See 4 more Smart Citations
“…This device has similar steps to Turbuhaler ® , and in a study with 165 patients with asthma and COPD, both devices had more incorrect applications compared with Diskus ® or Ellipta ® (28). Breezhaler ® requires an inspiratory flow greater than 50 L/min for the powder dispersion (56). This is higher than the inspiratory flow rated needed to action the Synchrobreathe device.…”
Section: Breezhaler ®mentioning
confidence: 96%
“…Advantages of this device are its portability and compact use, and its breath actuated action, which does not require coordination, and propellant free characteristics. Ellipta ® requires more than 30 L/min to trigger the medication (56), which could be an issue during exacerbation episodes or advanced stages of disease (51). A study from the Netherlands, with 567 patients with COPD and 162 with asthma, assessed the proportion of patients that made critical and overall mistakes using Ellipta ® and other commonly used inhaler devices such as Diskus ® , metered dose inhalers (MDI), Turbuhaler ® and Breezhaler ® .…”
Section: Synchrobreathe ®mentioning
confidence: 99%
See 3 more Smart Citations