Assessment of Left Ventricular Function and Mass on Free-Breathing Compressed Sensing Real-Time Cine Imaging

Abstract: stolic volume (EDV) and, consequently, variations in stroke volume (SV) and ejection fraction (EF) relative to ECG-gated retrospective standard cine MRI. 10 To overcome this limitation, imaging data have been acquired over 2 heart beats, thus capturing the complete end-diastole between the first and second heart beats. 10 Given that CS cine MRI has the advantage of being inherently insensitive to respiratory motion because of single-shot acquisition, 11,12 it is suitable for free-breathing (FB) imaging. The pu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

2
28
0
2

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(32 citation statements)
references
References 26 publications
2
28
0
2
Order By: Relevance
“…Nevertheless, the biases were all below 5% and would be expected to have minimal effect on clinical decision making. More importantly, the limits of agreement were narrow compared to previously described real-time methods (including those that utilize CS) [ 6 , 29 ]. We believe that this is due to the high spatial and temporal resolution of our spiral real-time sequence, which was only slightly lower than the standard breath hold sequence.…”
Section: Discussionmentioning
confidence: 96%
“…Nevertheless, the biases were all below 5% and would be expected to have minimal effect on clinical decision making. More importantly, the limits of agreement were narrow compared to previously described real-time methods (including those that utilize CS) [ 6 , 29 ]. We believe that this is due to the high spatial and temporal resolution of our spiral real-time sequence, which was only slightly lower than the standard breath hold sequence.…”
Section: Discussionmentioning
confidence: 96%
“…We demonstrated this is feasible using C-SENSE. C-SENSE is vendor provided, boasting faster image acquisition [32,33] and greater robustness to respiratory motion [19] than standard parallel imaging techniques. Our C-SENSE protocol's ability to assess biventricular haemodynamics and great vessel flow, which could be used to quantify valvular flow/regurgitant flow, in response to incremental exercise could theoretically provide a comprehensive assessment in valvular and congenital heart disease.…”
Section: Discussionmentioning
confidence: 99%
“…Unfortunately, the un-gated real-time technique requires specialist software (for post hoc cardiac and respiratory gating) and prolonged post processing and analysis time, thus decreasing clinical utility and widespread attainability. Compressed SENSE (C-SENSE) is a novel parallel imaging technique, robust to respiratory motion and allows fast image acquisition whilst maintaining high image quality [19]. To our knowledge [20], C-SENSE has not previously been utilised in Ex-CMR.…”
Section: Introductionmentioning
confidence: 99%
“…Although the accuracy and reproducibility of CMR bSSFP for the measurement of ventricular volumes, function, and cardiac mass is well established [17][18][19], the requirement for repeated BHs remains a limitation, especially in children and sedated patients. Accelerated cine CMR techniques (such as k-t BLAST, TPAT, TSENSE, and compressed sensing) have reported bias in left ventricular (LV) volumes, function, and LV mass due to spatiotemporal blurring and temporal filtering [20][21][22][23][24][25][26]. Free-breathing (FB) respiratory triggered retrospectively cardiac gated cine bSSFP sequences have been reported to provide biventricular volumes, function, and LV mass comparable to BH acquisitions with a SENSE acceleration factor of 2 in adults and children [27,28].…”
Section: Introductionmentioning
confidence: 99%