2015
DOI: 10.1016/j.ultrasmedbio.2015.04.014
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of Liver Fibrosis with 2-D Shear Wave Elastography in Comparison to Transient Elastography and Acoustic Radiation Force Impulse Imaging in Patients with Chronic Liver Disease

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

6
75
2
2

Year Published

2017
2017
2020
2020

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 90 publications
(87 citation statements)
references
References 32 publications
6
75
2
2
Order By: Relevance
“…Two patients suffered from polycystic liver disease; therefore, it was not possible to perform liver stiffness measurement. Liver fibrosis stage (F1–F4) was derived from the liver stiffness values in kPa obtained by shear-wave elastography based on the table provided by the device manufacturer [24]. Six patients had liver cirrhosis; all six cirrhotic patients were infected with genotype 1b and had well compensated liver disease with no signs of proteosynthetic dysfunction (albumin, bilirubin, and prothrombin time values within normal ranges), ascites, or encephalopathy.…”
Section: Methodsmentioning
confidence: 99%
“…Two patients suffered from polycystic liver disease; therefore, it was not possible to perform liver stiffness measurement. Liver fibrosis stage (F1–F4) was derived from the liver stiffness values in kPa obtained by shear-wave elastography based on the table provided by the device manufacturer [24]. Six patients had liver cirrhosis; all six cirrhotic patients were infected with genotype 1b and had well compensated liver disease with no signs of proteosynthetic dysfunction (albumin, bilirubin, and prothrombin time values within normal ranges), ascites, or encephalopathy.…”
Section: Methodsmentioning
confidence: 99%
“…Szükség lenne olyan nem invazív biomarker vagy pontrendszer rutingyakorlatba való átültetésére is, amely segítséget nyújtana a bélbetegségek során létrejö-vő májkárosodás diagnózisának, monitorozásának és prognózisának megítélésére [31][32][33][34][35][36].…”
Section: áBraunclassified
“…In addition, a recent study reported that liver stiffness (LS) measurements using TE have also shown the capability to predict the 5-year survival of patients with chronic hepatitis C [18]. According to one recent study comparing the accuracies of various US elastography techniques for the staging of liver fibrosis, TE, acoustic radiation force impulse imaging, and 2D-SWE were shown to be comparably effective methods for the noninvasive assessment of liver fibrosis [16]. However, in contrast to TE, point SWE and 2D-SWE can provide real-time B-mode US imaging which can aid in the planning and guidance of interventional procedures including RFA, and LS measurements obtained through SWE can easily be linked to RFA procedures [19].…”
Section: Introductionmentioning
confidence: 99%
“…However, in contrast to TE, point SWE and 2D-SWE can provide real-time B-mode US imaging which can aid in the planning and guidance of interventional procedures including RFA, and LS measurements obtained through SWE can easily be linked to RFA procedures [19]. Moreover, 2D-SWE allows real-time bidimensional assessment of LS in larger regions, and therefore LS values measured by 2D-SWE can provide information regarding the degree of liver fibrosis [15,16,19]. We therefore hypothesized that LS values measured by 2D-SWE might be a significant predictive factor for the clinical outcome of RFA in patients with HCCs.…”
Section: Introductionmentioning
confidence: 99%