2020
DOI: 10.30526/33.1.2383
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of Long Distance Chasing Photometer (NAG-ADF-300-2) by Estimating the Drug Atenolol with Povidone Iodine Via CFIA

Abstract: Atenolol was used with povidone iodine to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between atenolol and povidone iodine in an aqueous medium. Optimum parameters was studied to increase the sensitivity development of method. Calibration graph was linear in the range of 2-19 mmol/L for cell A and 5-19 mmol/L for cell B. Limit of detection 146.4848 ng/55 µL and 2.6600 µg/200… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 15 publications
0
2
0
Order By: Relevance
“…Analytical systems by flow injection are more suitable for everyday use in quality control laboratories for the production of pharmaceutical preparations due to their simplicity of work, speed, sensitivity, and less consumption of reagents, sample samples, and other chemicals when compared to other methods of chemical analysis. This study describes a simple, sensitive, fast, low-contamination, easy-to-operate analytical method for determining CAP within the continuous flow injection analysis (CFIA) technique [34][35][36][37][38][39][40]. Captopril was estimated after its interaction with ammonium by studying the precipitate formed as a result of the oxidation of CAP in an acidic medium using homemade Ayah 6SX1-ST-2D solar cell CFI analyzer [41], which was used in previous studies for the determination of some drugs [42][43][44][45][46][47].…”
Section: Introductionmentioning
confidence: 99%
“…Analytical systems by flow injection are more suitable for everyday use in quality control laboratories for the production of pharmaceutical preparations due to their simplicity of work, speed, sensitivity, and less consumption of reagents, sample samples, and other chemicals when compared to other methods of chemical analysis. This study describes a simple, sensitive, fast, low-contamination, easy-to-operate analytical method for determining CAP within the continuous flow injection analysis (CFIA) technique [34][35][36][37][38][39][40]. Captopril was estimated after its interaction with ammonium by studying the precipitate formed as a result of the oxidation of CAP in an acidic medium using homemade Ayah 6SX1-ST-2D solar cell CFI analyzer [41], which was used in previous studies for the determination of some drugs [42][43][44][45][46][47].…”
Section: Introductionmentioning
confidence: 99%
“…There are several methods for estimating diphenhydramine hydrochloride in literature; we mention some of them: spectrophotometric methods 6,7 , chromatographic methods [8][9][10][11] , flow injection 12,13 and potentiometric methods 14 . In this study, a new method was introduced within the continuous flow injection analysis technique [15][16][17][18] ,using homemade cells [19][20][21][22] , which depends on fluorescence or turbidity [23][24][25][26] as it is an easy, simple, sensitive, safe and inexpensive method to control the quality of DPH-containing drug tablets using homemade Ayah 6S×1-ST-2D solar cell CFI analyzer 27 , which has been successfully used in the determination of some drugs and some elements 28 . The study aims to present a simple, easy-to-work, environmentfriendly, low-cost, repeatable and high recovery percentage analytical method for diphenhydramine hydrochloride (DPH).…”
Section: Introductionmentioning
confidence: 99%