2018
DOI: 10.26480/jcleanwas.02.2018.16.18
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of Marine Water Quality Index in Mangrove Estuarine: Case Study in Setiu River Estuary

Abstract: This study provides information on marine water quality index in the Setiu River estuary. Mangrove estuarine and river mouth water are classified in Class E in MWQI. The subsequent MWQI with scales among 0 to 100 will define the grouping of the marine water quality from "Excellent" to "Poor". Six sampling station has been choosing and the sampling activity has been done from July 2016 to January 2017. Post-hoc Tukey HSD test calculates by evaluating whether MWQI for ST1 is more than the critical MWQI value for… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 6 publications
0
2
0
1
Order By: Relevance
“…The link between O&G and WQI is mostly due to the environmental and health hazards connected with these pollutants. According to Samsudin and Azid (2018), the use of WQI is a straightforward procedure that offers an appropriate assessment of water quality.…”
Section: Discussionmentioning
confidence: 99%
“…The link between O&G and WQI is mostly due to the environmental and health hazards connected with these pollutants. According to Samsudin and Azid (2018), the use of WQI is a straightforward procedure that offers an appropriate assessment of water quality.…”
Section: Discussionmentioning
confidence: 99%
“…All the reagents were added to the prepared 7 kg soil in pots (25 cm × 14 cm × 18 cm) according to the concentration of each treatment. In order to ensure sufficient nutrients for plant growth, 0.2 g of urea and 0.1 g of potassium dihydrogen phosphate were applied to every kg of soil (Samsudin et al, 2018). The soil was permitted to equilibrate for 30 d after lead and cadmium contamination.…”
Section: Methodsmentioning
confidence: 99%
“…Para ello, se toma en cuenta el uso dado, la ocurrencia de procesos naturales, y las actividades antropogénicas cercanas (Vivas-Aguas & Navarrete-Ramírez, 2014). La mayoría de estos estudios se basa en la determinación de variables fisicoquímicas como oxígeno disuelto (OD), temperatura, turbidez, salinidad; determinación de las concentraciones de nitrato y fosfato, cantidad de sólidos suspendidos totales (SST), demanda bioquímica de oxígeno (DBO), presencia de hidrocarburos derivados del petróleo o de elementos tóxicos, al igual que de variables microbiológicas, como coliformes fecales (CF), Escherichia coli (E. coli) y Enteroccocus faecalis (E. faecalis) (Nguyen & Sevando, 2019;Samsudin & Azid, 2018;Tanjung et al, 2019;Vivas-Aguas & Navarrete-Ramírez, 2014).…”
unclassified