2023
DOI: 10.1016/j.buildenv.2023.110037
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of melanopsin-based quantities: Comparison of selected design tools and validation against on-field measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 58 publications
0
4
0
Order By: Relevance
“…Based on the CIE standard S026/E:2018 [45], the units of EML were converted to mel-EDI with units in lux. Mel-EDI is a scalar multiplier of melanopic lux (EML), and mel-EDI can be easily obtained by multiplying by 0.9058 the value of the melanopic illuminance calculated according to the method proposed by Lucas et al [42,46,47]. As a consequence, the units reported in this study will be the mel-EDI.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Based on the CIE standard S026/E:2018 [45], the units of EML were converted to mel-EDI with units in lux. Mel-EDI is a scalar multiplier of melanopic lux (EML), and mel-EDI can be easily obtained by multiplying by 0.9058 the value of the melanopic illuminance calculated according to the method proposed by Lucas et al [42,46,47]. As a consequence, the units reported in this study will be the mel-EDI.…”
Section: Methodsmentioning
confidence: 99%
“…Bellia et al [42] studied the accuracy and applicability of the software ALFA. For the purpose of evaluating non-visual effects, two different approaches, based on the use of ALFA and DIALux, were described, validated against on-field measurements, and compared.…”
Section: Methodsmentioning
confidence: 99%
“…To show compliance with building codes and design criteria, simulation software has become the primary tool in the fields of environmental sustainability, and lighting design (Azhar and MBC, 2009; Ibarra and Reinhart, 2009). The fundamental reason for utilizing DIALux for lighting simulation and calculations in the study was that it is the primary simulation tool utilized by designers (Bellia et al. , 2023), for its fast calculation abilities (Hemmerling et al.…”
Section: Methodsmentioning
confidence: 99%
“…To show compliance with building codes and design criteria, simulation software has become the primary tool in the fields of environmental sustainability, and lighting design (Azhar and MBC, 2009;Ibarra and Reinhart, 2009). The fundamental reason for utilizing DIALux for lighting simulation and calculations in the study was that it is the primary simulation tool utilized by designers (Bellia et al, 2023), for its fast calculation abilities (Hemmerling et al, 2023), ability to provide a platform to design lighting systems that appeal to users (Guerry et al, 2019), reliable use to test different lighting devices abilities like different lenses used in LED fittings (Kee Xiao Ying and Lim, 2022), and its appeal stems from the fact that it is free, user-friendly, and imports photometric data from about 190 manufacturers ("DIALux", 2023). DIALux can compute the electric light aspects, daylighting, and lighting system power consumptions.…”
Section: Modeling and Simulationmentioning
confidence: 99%