1998
DOI: 10.1002/(sici)1097-0215(19981218)79:6<629::aid-ijc13>3.0.co;2-1
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of microsatellite instability in urine in the detection of transitional-cell carcinoma of the bladder

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
22
0
2

Year Published

2000
2000
2006
2006

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 66 publications
(27 citation statements)
references
References 18 publications
3
22
0
2
Order By: Relevance
“…The primer sequences used for PCR analyses (AB Applied Biosystems, Les Ulis, France) are available from authors upon request. For microsatellite analysis one primer of each marker pair was end‐labeled with 1 of the following fluorophores: 6‐FAM, NED® or HEX (AB Applied Biosystems) PCR was conducted essentially as described previously 15. Briefly, for each microsatellite marker, equal amounts of DNA (20 ng each of constitutional and urine‐extracted) were subjected simultaneously in 2 different PCR tubes to 30–35 cycles of amplification in a Hybaid Touch Down thermocycler (Hybaid, Teddington, UK), as follows: 95°C for 30 sec, followed by the appropriate annealing temperature (52–60°C) for 1 min, an extension step at 72°C for 1 min and a final extension step at 72°C for 5 min.…”
Section: Methodssupporting
confidence: 94%
See 2 more Smart Citations
“…The primer sequences used for PCR analyses (AB Applied Biosystems, Les Ulis, France) are available from authors upon request. For microsatellite analysis one primer of each marker pair was end‐labeled with 1 of the following fluorophores: 6‐FAM, NED® or HEX (AB Applied Biosystems) PCR was conducted essentially as described previously 15. Briefly, for each microsatellite marker, equal amounts of DNA (20 ng each of constitutional and urine‐extracted) were subjected simultaneously in 2 different PCR tubes to 30–35 cycles of amplification in a Hybaid Touch Down thermocycler (Hybaid, Teddington, UK), as follows: 95°C for 30 sec, followed by the appropriate annealing temperature (52–60°C) for 1 min, an extension step at 72°C for 1 min and a final extension step at 72°C for 5 min.…”
Section: Methodssupporting
confidence: 94%
“…DNA of Family 134702 (CEPH, Paris, France) was used as control. We used a diagnostic set of polymorphic microsatellite markers mapped to chromosomes 4 (D4S243, FGA), 6 (ACTBP2), 9 (D9S162, D9S171, D9S747, IFNA), 14 (MJD52), 16 (D16S310, D16S476), 18 (D18S51, MBP) and 21 (D21S1245) as described previously 15. The primer sequences used for PCR analyses (AB Applied Biosystems, Les Ulis, France) are available from authors upon request.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This assay was negative in all 10 patients without evidence of cancer (Steiner et al, 1997). Subsequent studies from other investigators have confirmed the reliability of the PCR-based microsatellite analysis of the urine sediments, with 83% sensitivity and 100% specificity (Mourah et al, 1998). These studies support further study of microsatellite analysis of urine sediment DNA for the detection of primary and recurrent bladder cancer.…”
Section: Bladder Cancermentioning
confidence: 57%
“…Steiner et al [111] correctly diagnosed 20 of 21 patients being followed for BC recurrence using microsatellite analysis with 20 markers in a blinded fashion. Mowah et al [112] reported similar results by detecting microsatellite instability in 10 of 12 patients with BC.…”
Section: Microsatellite Instabilitymentioning
confidence: 67%