2022
DOI: 10.3390/ijerph19106199
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of On-Board and Laboratory Gas Measurement Systems for Future Heavy-Duty Emissions Regulations

Abstract: Road transport contributes significantly to air pollution in cities. Regulations across the globe continuously reduce the limits that vehicles need to respect during their lifetimes. Furthermore, more pollutants are being subject to control with new regulations and, most important, testing tends to be done under real-world conditions on the road. In this study, various portable systems were compared with laboratory-grade equipment with a wide range of emissions, focusing on the lower end, where the measurement… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 48 publications
2
2
0
Order By: Relevance
“…For NH 3 , the humidity in the exhaust gas plays an important role, as it condensates on the tubing, sampling probes, and sampling lines of the instruments, where NH 3 can be adsorbed and later released (see Appendix A, Figure A2). The 10% difference is acceptable and in agreement with the literature [32,69]. Even though the calibration of the instruments can be much more accurate, the dynamic phenomena described previously play an important role.…”
Section: Resultssupporting
confidence: 88%
See 3 more Smart Citations
“…For NH 3 , the humidity in the exhaust gas plays an important role, as it condensates on the tubing, sampling probes, and sampling lines of the instruments, where NH 3 can be adsorbed and later released (see Appendix A, Figure A2). The 10% difference is acceptable and in agreement with the literature [32,69]. Even though the calibration of the instruments can be much more accurate, the dynamic phenomena described previously play an important role.…”
Section: Resultssupporting
confidence: 88%
“…A closer look at the data reveals that the two instruments at the tailpipe (FTIR and NDIR instruments) were within 5 g/km or 5%, further supporting that the remaining 5% differences from the dilution tunnel instrument were mainly due to uncertainties in the exhaust flow determination. Nevertheless, 5-10% differences in CO2 measurements are acceptable and of the same order of values in other studies with similar technologies [32,69,77,97,[109][110][111][112][113].…”
Section: Resultssupporting
confidence: 64%
See 2 more Smart Citations