2018
DOI: 10.31661/jbpe.v0i0.400
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of Photoplethysmography Method in Extraction of Hemoglobin Concentration

Abstract: Background: The importance of continuous monitoring along with rapid and accurate notification of changes in blood components such as hemoglobin concentration, especially in acute situations, encourages researchers to use non-invasive methods for measuring.Objective: This study was aimed to investigate the correlation between hemoglobin concentration and photoplethysmogram (PPG) and the possibility of measuring it by an optical method.Material and Methods: In this applied study, a PPG signal was simultaneously… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…First, although the artifacts caused by respiratory motion and esophageal peristalsis hidden in the transesophageal dPPG signal were removed by a filter, the nonpulsatile DC component had contamination of background light absorption caused by surrounding tissues, such as the esophageal mucosa and smooth muscle between the transesophageal oximetry sensor and the descending aorta [ 12 , 27 , 28 ]. Similar to the principle of cerebral oxygen saturation monitoring, it may be possible to remove background light absorption contamination by setting both near and far photodetectors or adding different wavelengths related to Hb light absorption, but these require further investigation [ 22 , 29 , 30 ]. In addition, the infusion of colloids appears to affect the light absorption of hemoglobin [ 4 ].…”
Section: Discussionmentioning
confidence: 99%
“…First, although the artifacts caused by respiratory motion and esophageal peristalsis hidden in the transesophageal dPPG signal were removed by a filter, the nonpulsatile DC component had contamination of background light absorption caused by surrounding tissues, such as the esophageal mucosa and smooth muscle between the transesophageal oximetry sensor and the descending aorta [ 12 , 27 , 28 ]. Similar to the principle of cerebral oxygen saturation monitoring, it may be possible to remove background light absorption contamination by setting both near and far photodetectors or adding different wavelengths related to Hb light absorption, but these require further investigation [ 22 , 29 , 30 ]. In addition, the infusion of colloids appears to affect the light absorption of hemoglobin [ 4 ].…”
Section: Discussionmentioning
confidence: 99%
“…First, although the artifacts caused by respiratory motion and esophageal peristalsis hidden in the transesophageal dPPG signal were removed by a lter, the nonpulsatile DC component had contamination of background light absorption caused by surrounding tissues, such as the esophageal mucosa and smooth muscle between the transesophageal oximetry sensor and the descending aorta [12,27,28]. Similar to the principle of cerebral oxygen saturation monitoring, it may be possible to remove background light absorption contamination by setting both near and far photodetectors or adding different wavelengths related to Hb light absorption, but these require further investigation [22,29,30]. In addition, the infusion of colloids appears to affect the light absorption of hemoglobin [4].…”
Section: Discussionmentioning
confidence: 99%
“…Using NIR-spectroscopy and photodetectors, photoplethysmograms (PPG)-a measure of the variations in the volume of blood with each cardiac cycle applying optical properties of blood, can be generated. Various biomedical applications, including Hgb level measurement, use PPG signals captured from fingertips using a PPG probe, or a pulse-oximeter, or sensors [28]- [31].…”
Section: B Photoplethysmography (Ppg) Signal Based Methodsmentioning
confidence: 99%