Assessment of temporary cerebral effects induced by focused ultrasound with optical coherence tomography angiography

Abstract: Focused ultrasound (FUS) in combination with microbubbles temporally and locally increases the permeability of the blood-brain barrier (BBB) for facilitating drug delivery. However, the temporary effects of FUS on the brain microstructure and microcirculation need to be addressed. We used label-free optical coherence tomography (OCT) and OCT angiography (OCTA) to investigate the morphological and microcirculation changes in mouse brains due to FUS exposure at different power levels. Additionally, the recovery … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 25 publications
0
3
0
Order By: Relevance
“…Then, the measured mouse skin thicknesses at these twenty-one transverse locations in each 2D OCT image were averaged to obtain a mean value of skin thickness. Additionally, the method for estimating the vessel density is similar to that in the previous report [ 27 ]. Three subareas in each OCTA image for each group (as marked by colored squares in Figs.…”
Section: Discussionmentioning
confidence: 96%
See 1 more Smart Citation
“…Then, the measured mouse skin thicknesses at these twenty-one transverse locations in each 2D OCT image were averaged to obtain a mean value of skin thickness. Additionally, the method for estimating the vessel density is similar to that in the previous report [ 27 ]. Three subareas in each OCTA image for each group (as marked by colored squares in Figs.…”
Section: Discussionmentioning
confidence: 96%
“…C: collimator; DC: dispersion compensator; M: mirror; G: two-axis galvanometer; SL: scanning lens. [ 27 ]. A 1060-nm swept source (SSOCT-1060, AXSUN Technologies Inc., MA, USA) with a scanning bandwidth of 100 nm was utilized, corresponding to a longitudinal resolution of 5 μm in air.…”
Section: Experimental Setup and Methodsmentioning
confidence: 99%
“…Faster dextran accumulation (which occurred instantaneously with BBB disruption) was found to be accompanied with absolute and immediate BBB disruption, whereas slower dextran accumulation (5–15 min postsonication) occurred over a wide range of ultrasound intensities [ 29 , 30 ]. Tsai et al recently used swept-scan optical coherence tomography and real-time 3D angiography to reveal transient cerebral vessel dilation during FUS-BBBO, where the degree of vessel dilation was correlated with the FUS intensity [ 31 ].…”
Section: Bbb Opening By Focused Ultrasoundmentioning