2016
DOI: 10.1016/j.echo.2016.04.012
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of Ventricular Septal Defect Size and Morphology by Three-Dimensional Transthoracic Echocardiography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0
2

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(7 citation statements)
references
References 26 publications
0
5
0
2
Order By: Relevance
“…Although the diagnostic value of traditional 3DE has been confirmed for relatively common septal defects ( Saric et al, 2010 ; Charakida et al, 2014 ; Cossor et al, 2015 ; Hadeed et al, 2016 ), TrueVue plus a light source makes not only the defect boundary clearer, but also makes the range for the soft rim more visible. In TrueVue Glass, adjusting the transparency highlights the origin and extent of an atrial or ventricular shunt.…”
Section: Discussionmentioning
confidence: 99%
“…Although the diagnostic value of traditional 3DE has been confirmed for relatively common septal defects ( Saric et al, 2010 ; Charakida et al, 2014 ; Cossor et al, 2015 ; Hadeed et al, 2016 ), TrueVue plus a light source makes not only the defect boundary clearer, but also makes the range for the soft rim more visible. In TrueVue Glass, adjusting the transparency highlights the origin and extent of an atrial or ventricular shunt.…”
Section: Discussionmentioning
confidence: 99%
“…3DTTE/3DTEE may be particularly useful before and during percutaneous VSD closure. [29][30][31] CS is a terrible complication of PIVSD accompanied by a high mortality rate of approximately 89%. 2 Our data suggest that patients who developed VSD and died were more likely to have CS before TCC.…”
Section: Discussionmentioning
confidence: 99%
“…Many analysts now argue 3DTTE/3DTEE has been more successful than 2DTTE for evaluating VSDs following AMI; for example, they argue that the shape of the VSD and its changes during the cardiac cycle can be visually and quantitatively displayed. 3DTTE/3DTEE may be particularly useful before and during percutaneous VSD closure 29–31 …”
Section: Discussionmentioning
confidence: 99%
“…Two-dimensional (2D) echocardiography (2DE) underestimates VSD size compared with three-dimensional (3D) echocardiography (3DE) and surgical measures. [1][2][3] We hypothesized that VSD area obtained from 3DE could better discriminate shunt severity than VSD diameters.…”
Section: Ventricularmentioning
confidence: 99%