2019
DOI: 10.29007/lqsv
|View full text |Cite
|
Sign up to set email alerts
|

Assistive Robotic Hand Orthosis (ARHO) controlled with EMG: evaluation of a preliminary prototype

Abstract: — Hand impairment severely limits basic activities of daily living (ADL). The use of motorized hand orthoses may provide enough functional assistance to perform basic tasks, such as grasping objects. Several prototypes have been proposed in the last decade, but there are still no solutions with the desired features regarding the weight, wearability and functionality. This paper describes the overall implementation of a prototype of an assistive robotic hand orthosis (ARHO) for object grasping, that can be trig… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 6 publications
0
2
0
Order By: Relevance
“…Three studies did not provide unambiguous information about the used control method (Pedrocchi et al, 2013 ; Mohammadi et al, 2018 ; Rose and O'Malley, 2019 ). A total of 15 studies used pattern recognition-EMG techniques to control hand orthoses (Ngeo et al, 2013 ; Kawase et al, 2017 ; Meeker et al, 2017 ; Siu et al, 2018 ; Burns et al, 2019 ; Dwivedi et al, 2019 ; Farinha et al, 2019 ; Lu et al, 2019 ; Park et al, 2019 , 2020 ; Secciani et al, 2019 ; Zhang et al, 2019 ), and wrist, elbow, or shoulder orthoses (Kiguchi, 2007 ; Kawase et al, 2017 ; Kilic, 2017 ; Lotti et al, 2020 ). To do so, up to 12 EMG channels were used (Kiguchi, 2007 ), controlling up to a maximum of six different states (Dwivedi et al, 2019 ; Lu et al, 2019 ; Zhang et al, 2019 ).…”
Section: Reviewmentioning
confidence: 99%
See 1 more Smart Citation
“…Three studies did not provide unambiguous information about the used control method (Pedrocchi et al, 2013 ; Mohammadi et al, 2018 ; Rose and O'Malley, 2019 ). A total of 15 studies used pattern recognition-EMG techniques to control hand orthoses (Ngeo et al, 2013 ; Kawase et al, 2017 ; Meeker et al, 2017 ; Siu et al, 2018 ; Burns et al, 2019 ; Dwivedi et al, 2019 ; Farinha et al, 2019 ; Lu et al, 2019 ; Park et al, 2019 , 2020 ; Secciani et al, 2019 ; Zhang et al, 2019 ), and wrist, elbow, or shoulder orthoses (Kiguchi, 2007 ; Kawase et al, 2017 ; Kilic, 2017 ; Lotti et al, 2020 ). To do so, up to 12 EMG channels were used (Kiguchi, 2007 ), controlling up to a maximum of six different states (Dwivedi et al, 2019 ; Lu et al, 2019 ; Zhang et al, 2019 ).…”
Section: Reviewmentioning
confidence: 99%
“…In 21 studies, conventional manual triggers such as buttons/switches (Ochoa et al, 2009 ; Pedrocchi et al, 2013 ; Ambrosini et al, 2014a ; Yap et al, 2016 , 2017a ; Meeker et al, 2017 ; Fardipour et al, 2018 ; Otten et al, 2018 ; Butzer et al, 2019 , 2021 ; Farinha et al, 2019 ; Correia et al, 2020 ; Gerez et al, 2020 ; Muehlbauer et al, 2021 ), joysticks (Hasegawa and Oura, 2011 ; Dalla Gasperina et al, 2019 ; Ismail et al, 2019 ; Tiseni et al, 2019 ), or touchscreens (Yap et al, 2017b ; Mohammadi et al, 2018 ; Sandison et al, 2020 ) have been used.…”
Section: Reviewmentioning
confidence: 99%