2022
DOI: 10.1016/j.jheap.2022.05.005
|View full text |Cite
|
Sign up to set email alerts
|

ASTRI Mini-Array core science at the Observatorio del Teide

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
28
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 37 publications
(41 citation statements)
references
References 294 publications
0
28
0
Order By: Relevance
“…We note that the ASTRI Mini-Array performance remains almost stable across the 10°FoV, with a degradation at its edge by roughly a factor of two [3,6]. On the other side, the EASs have 2 sr field of view, but their energy and angular resolution in the same energy range as the ASTRI Mini-Array (about 10 TeV) are at least a factor of 3-4 worse, making the ASTRI Mini-Array extremely competitive in studying the morphology of extended sources, crowded fields, and accurately monitoring multiple targets in the same pointing.…”
Section: Introduction: the Astri Mini-arraymentioning
confidence: 79%
See 3 more Smart Citations
“…We note that the ASTRI Mini-Array performance remains almost stable across the 10°FoV, with a degradation at its edge by roughly a factor of two [3,6]. On the other side, the EASs have 2 sr field of view, but their energy and angular resolution in the same energy range as the ASTRI Mini-Array (about 10 TeV) are at least a factor of 3-4 worse, making the ASTRI Mini-Array extremely competitive in studying the morphology of extended sources, crowded fields, and accurately monitoring multiple targets in the same pointing.…”
Section: Introduction: the Astri Mini-arraymentioning
confidence: 79%
“…The energy range above a few TeVs is the right spot for the ASTRI Mini-Array. In [3] we simulated a GRB 190114C-like source with a prompt energy of 3 × 10 53 erg placed at = 0.1 and = 0.25 (GRB 221009A is at = 0.15) and we predicted the capability to detect photons up to and above 10 TeV within few minutes from the burst.…”
Section: The Astri Mini-array Scientific Pillarsmentioning
confidence: 99%
See 2 more Smart Citations
“…Its angular resolution (0.05 • at 10 TeV) will be fundamental for a morphological reconstruction of extended sources like SNRs, PWNe and MSCs. Therefore, soon, the ASTRI Mini-Array will have a vast discovery space in the field of extreme 𝛾-rays, up to 100 TeV and beyond [14][15][16].…”
Section: The Pevatron Context and The Role Of Astri Mini-arraymentioning
confidence: 99%