2001
DOI: 10.1049/el:20010508
|View full text |Cite
|
Sign up to set email alerts
|

Asymmetric Mach-Zehnder germano-silicate channelwaveguide interferometersfor quantum cryptography systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
8
0

Year Published

2004
2004
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 1 publication
0
8
0
Order By: Relevance
“…An alternative approach to the aforementioned problems based on a one-way interferometer using integrated-optic AMZIs [26][27][28][29] was recently reported. By applying a planar lightwave circuit (PLC), the instability due to the phase drift inherent in a one-way QKD system and the polarization drift in the link fiber were eliminated without introducing 4 any complex active compensation mechanisms.…”
Section: Michelson Interferometer and Faraday Mirrors To Develop An Imentioning
confidence: 99%
“…An alternative approach to the aforementioned problems based on a one-way interferometer using integrated-optic AMZIs [26][27][28][29] was recently reported. By applying a planar lightwave circuit (PLC), the instability due to the phase drift inherent in a one-way QKD system and the polarization drift in the link fiber were eliminated without introducing 4 any complex active compensation mechanisms.…”
Section: Michelson Interferometer and Faraday Mirrors To Develop An Imentioning
confidence: 99%
“…In this letter, we propose a unidirectional system using integrated-optic interferometers based on the planar lightwave circuit (PLC) technology as a solution to this conflict between stability and transmission distance [12]. We have demonstrated single-photon interference with sufficiently high visibility for constructing a practical QKD system up to 150 km.…”
mentioning
confidence: 99%
“…Two components were joined to form a single time-division interferometer for optical pulses. The composite interferometer displayed a high fringe contrast ratio of 1:200 production that is eminently appropriate for use in compact, low-error-rate quantum cryptography systems [7]. It provides the academic and the applied communities a compendium and a research resource with significant insights and inspiration for innovative scientific education, investigation, and collaboration, overcoming "hard problems" among the emerging challenges today and in the future [8].…”
Section: Mathematics Subject Classification 94-xx 1 Introductionmentioning
confidence: 99%