2017
DOI: 10.1038/s41598-017-16142-6
|View full text |Cite
|
Sign up to set email alerts
|

Asymmetrical bipolar nanosecond electric pulse widths modify bipolar cancellation

Abstract: A bipolar (BP) nanosecond electric pulse (nsEP) exposure generates reduced calcium influx compared to a unipolar (UP) nsEP. This attenuated physiological response from a BP nsEP exposure is termed “bipolar cancellation” (BPC). The predominant BP nsEP parameters that induce BPC consist of a positive polarity (↑) front pulse followed by the delivery of a negative polarity (↓) back pulse of equal voltage and width; thereby the duration is twice a UP nsEP exposure. We tested these BPC parameters, and discovered th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
36
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 39 publications
(41 citation statements)
references
References 22 publications
5
36
0
Order By: Relevance
“…To test if this reversal is partially due to symmetry among the BP nsEPs, we exposed CHO‐K1 cells to a ↑900↓300 nsEP with a lengthened interphase interval. In comparison to a ↑600 UP nsEP exposure, this BP nsEP eliminates pulse symmetry, maintains a doubling of total pulse duration, and was previously described to yield BPC of YP‐1 uptake by 55% [Valdez et al, ]. When we separated the ↑900↓300 nsEP pulse by 10 μs and 10 ms, we observed YP‐1 uptake was differentially reduced by 41% and 14%, respectively (Fig.…”
Section: Resultsmentioning
confidence: 53%
See 4 more Smart Citations
“…To test if this reversal is partially due to symmetry among the BP nsEPs, we exposed CHO‐K1 cells to a ↑900↓300 nsEP with a lengthened interphase interval. In comparison to a ↑600 UP nsEP exposure, this BP nsEP eliminates pulse symmetry, maintains a doubling of total pulse duration, and was previously described to yield BPC of YP‐1 uptake by 55% [Valdez et al, ]. When we separated the ↑900↓300 nsEP pulse by 10 μs and 10 ms, we observed YP‐1 uptake was differentially reduced by 41% and 14%, respectively (Fig.…”
Section: Resultsmentioning
confidence: 53%
“…We previously observed BPC of YP‐1 uptake from the delivery of ↑300↓300, ↑600↓600, and ↑900↓900 nsEP exposures (Fig. ) [Valdez et al, ]. In this report, we increased the interphase interval between these symmetrical BP nsEP waveforms, and were able to alter their BPC effect on YP‐1 uptake (Fig.…”
Section: Discussionmentioning
confidence: 49%
See 3 more Smart Citations