2023
DOI: 10.1021/acs.analchem.3c00462
|View full text |Cite
|
Sign up to set email alerts
|

At-Home Saliva Sampling in Healthy Adults Using CandyCollect, a Lollipop-Inspired Device

Abstract: Respiratory infections are common in children, and there is a need for user-friendly collection methods. Here, we performed the first human subjects study using the CandyCollect device, a lollipop-inspired saliva collection device .We showed that the CandyCollect device can be used to collect salivary bacteria from healthy adults using Streptococcus mutans and Staphylococcus aureus as proof-of-concept commensal bacteria. We enrolled healthy adults in a nationwide (USA) remote study in which participants were s… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(14 citation statements)
references
References 32 publications
0
14
0
Order By: Relevance
“…In addition to SARS-CoV-2, saliva could serve as specimen for other respiratory viruses [34] such as Influenza viruses, Respiratory Syncytial Virus (RSV), Adenovirus, and Rhinovirus and even bacterial pathogens such as Group A streptococci causing strep throat, and Bordetella pertussis causing whooping cough [35]. This study suggests that the 18S rRNA could be a suitable IAC for other diagnostic tests that rely on saliva samples.…”
Section: Resultsmentioning
confidence: 99%
“…In addition to SARS-CoV-2, saliva could serve as specimen for other respiratory viruses [34] such as Influenza viruses, Respiratory Syncytial Virus (RSV), Adenovirus, and Rhinovirus and even bacterial pathogens such as Group A streptococci causing strep throat, and Bordetella pertussis causing whooping cough [35]. This study suggests that the 18S rRNA could be a suitable IAC for other diagnostic tests that rely on saliva samples.…”
Section: Resultsmentioning
confidence: 99%
“…All laboratory procedures were performed in accordance with Biosafety Level-2 laboratory practices and the University of Washington Site-Specific Bloodborne Pathogen Exposure Control Plan. CandyCollect devices and mouth swabs were processed as previously described; 10 additional details are in the Supplemental Material. Briefly, the material on the CandyCollect device was eluted by phosphate buffered saline (PBS) (Gibco™, Cat# 10010023) with 5% Proteinase K (Thermo Scientific™, Cat# EO0491); for mouth swab samples, S. pyogenes DNA was isolated using MagMAX™ Total Nucleic Acid Isolation Kit (ThermoFisher Scientific, Cat# AM1840) according to the protocol supplied by the manufacturer.…”
Section: Methodsmentioning
confidence: 99%
“…The process includes decreasing the chamber pressure to 0.20-0.25 mbar and adding oxygen gas while 70 W voltage is applied for 5 minutes. 9,10 Preparation of CandyCollect devices for human subjects study: CandyCollect devices were prepared as previously described with the exception of storage containers and candy mass. 9,10 Half of the patients (1-15) were sampled with CandyCollects made with 1.2-1.34 g isomalt candy, while the second half (16-30) were sampled with 0.45-0.57 g; procedures are duplicated here for convenience.…”
Section: Plasma Treatment Of Candycollect Devicesmentioning
confidence: 99%
See 2 more Smart Citations