2004
DOI: 10.1007/bf03006357
|View full text |Cite
|
Sign up to set email alerts
|

Atlas d’anatomie humaine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2005
2005
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 29 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…Non‐fractured external geometries of one hipbone and the sacrum were later imported into HyperMesh 12.0 (Altair Engineering, Troy, Michigan, USA) for both surface cleaning and mirroring to obtain a fully symmetrical intact pelvis considered suitable by experienced surgeons for conducting the study. Because of the difficulty in distinguishing soft tissues with Computed Tomography scans, both sacroiliac joints and the pubic symphysis were constructed in this very same software by linking the articular surfaces of bones according to anatomical observations from literature (Netter 2007, Becker et al 2010). Two spheres were created to represent each femoral head.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Non‐fractured external geometries of one hipbone and the sacrum were later imported into HyperMesh 12.0 (Altair Engineering, Troy, Michigan, USA) for both surface cleaning and mirroring to obtain a fully symmetrical intact pelvis considered suitable by experienced surgeons for conducting the study. Because of the difficulty in distinguishing soft tissues with Computed Tomography scans, both sacroiliac joints and the pubic symphysis were constructed in this very same software by linking the articular surfaces of bones according to anatomical observations from literature (Netter 2007, Becker et al 2010). Two spheres were created to represent each femoral head.…”
Section: Methodsmentioning
confidence: 99%
“…Each force acting on the pelvis computed by inverse dynamics was decomposed into three components along space direction. These components were implemented into an ANSYS Workbench FE model as direct or remote forces applied on surfaces of the geometries of bones for muscles (according to anatomical muscles attachments (Netter 2007, Drake et al 2014)) and to femoral heads as direct forces for left and right hip joint reaction forces. The global magnitudes are reported in Table 2 for information.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The ligations caused a decrease in the medullar blood flow and consequent cord ischemia. Some segmental arteries branch in anterior radiculomedullary arteries, which supply the anterior spinal artery (ASA) [10][11][12]. The terminal perforating capillaries from the ASA supply the grey matter's anterior horn and the white matter's anteromedial part, forming the vertical medullary network [10].…”
Section: Introductionmentioning
confidence: 99%