2015
DOI: 10.1088/1742-6596/591/1/012049
|View full text |Cite
|
Sign up to set email alerts
|

Atmospheric-Pressure Non-Thermal Plasma Jet for biomedical and industrial applications

Abstract: Abstract. In this work we present the development and evaluation of a low-cost DBD Plasma-JET reactor using Argon as carrier gas, this device is capable of generating a cold plasma plume several centimeters in length making it suitable for use directly in contact with objects and delicate materials, including living tissue.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 6 publications
0
6
0
Order By: Relevance
“…SHF power supplies are large-size and lowefficiency. Applying of HF sine voltage gives the opportunity of use of small-size power supplies, but in this case gas temperature can be lower than 40 ∘ C at high flow rate of working gas (> 3 L/min) [3]. Authors of works [4][5] produced high efficiency of excimer DBD lamps due to feeding of discharge by short pulsed voltage.…”
Section: Kne Energy and Physicsmentioning
confidence: 99%
“…SHF power supplies are large-size and lowefficiency. Applying of HF sine voltage gives the opportunity of use of small-size power supplies, but in this case gas temperature can be lower than 40 ∘ C at high flow rate of working gas (> 3 L/min) [3]. Authors of works [4][5] produced high efficiency of excimer DBD lamps due to feeding of discharge by short pulsed voltage.…”
Section: Kne Energy and Physicsmentioning
confidence: 99%
“…At lower frequencies, a high-frequency sine voltage has the benefit of requiring smaller-sized power supplies, currently using linear amplifiers. In this case, however, gas temperatures below 42 °C can be achieved at high working gas flow rates only (>3 L/min) [10]. Below, we consider modern power electronic circuits using switched solid-state semiconductors as a solution.…”
Section: Introductionmentioning
confidence: 99%
“…At average values, considering TBurst = 1/fBurst time (much longer than Tsw; see Equation ( 10)), the injected power is adjusted using the MBurst and Toff variables, with Equations ( 9) and (10) in the low-frequency domain, at fBurst.…”
mentioning
confidence: 99%
“…High voltage applied to the ring electrodes 2 ignites the gas discharge plasma inside the tube 1, and the gas flow 6 pushes the plasma out in the form of a jet 5. and inefficient. Sine HF voltage has the benefit of using power supplies that are more compact, but in this case gas temperatures lower than 40 °C can only be achieved at high flow rates of working gas (>3 L/min) [7].…”
Section: Testing Electrode System Of the Nonthermal Plasma Jetmentioning
confidence: 99%
“…Typically, SHF power supplies are bulky, expensive and inefficient. Sine HF voltage has the benefit of using power supplies that are more compact, but in this case gas temperatures lower than 40 • C can only be achieved at high flow rates of working gas (>3 L/min) [7].…”
Section: Introductionmentioning
confidence: 99%