Atrial fibrillation screening during automated blood pressure measurement—Comment on “Diagnostic accuracy of new algorithm to detect atrial fibrillation in a home blood pressure monitor”

Abstract: With the increasing longevity and prevalence of cardiovascular disease, such as hypertension and chronic heart failure, there is an emerging epidemic of atrial fibrillation (AF) in almost all communities.According to the worldwide estimation in 2010, the prevalence of AF was 0.596% in men and 0.373% in women, and the estimated number of patients with AF worldwide was 33.5 million. Several models of BP monitors from various manufacturers were developed with an added function of irregular heartbeat detection (Ta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 20 publications
0
9
0
Order By: Relevance
“…Automatic oscillometric blood pressure monitors with algorithms for detecting atrial fibrillation detect atrial fibrillation by checking the regularity of pulses 70. The Microlife BP monitor (Microlife USA, Dunedin, FL) is one of the best studied devices.…”
Section: Newer Detection Methodsmentioning
confidence: 99%
“…Automatic oscillometric blood pressure monitors with algorithms for detecting atrial fibrillation detect atrial fibrillation by checking the regularity of pulses 70. The Microlife BP monitor (Microlife USA, Dunedin, FL) is one of the best studied devices.…”
Section: Newer Detection Methodsmentioning
confidence: 99%
“…One device identifies possible AF when at least two of three consecutive measurements show pulse irregularity. Several studies addressed the diagnostic accuracy 51,68,71‐77 and the feasibility of this device as a screening tool 51,75,78 …”
Section: Mhealth Technologiesmentioning
confidence: 99%
“…Blood pressure (BP) measurements can be erratic when the pulse is irregular. This characteristic is utilized by automatic oscillometric BP monitors that derive heart rhythm regularity algorithmically 68 . Automated BP monitors have been used for opportunistic AF detection.…”
Section: Mhealth Technologiesmentioning
confidence: 99%
“…Blood pressure (BP) measurements can be erratic when the pulse is irregular. This characteristic is utilized by automatic oscillometric BP monitors that derive heart rhythm regularity algorithmically (Chen, Lei, & Wang, 2017). Automated BP monitors have been used for opportunistic AF detection.…”
Section: Oscillometrymentioning
confidence: 99%
“…One device identifies possible AF when at least two of three consecutive measurements show pulse irregularity. Several studies addressed the diagnostic accuracy , Chen, Lei, & Wang, 2017, Gandolfo, Balestrino, Bruno, Finocchi, & Reale, 2015, Kearley et al, 2014, Marazzi et al, 2012, Stergiou, Karpettas, Protogerou, Nasothimiou, & Kyriakidis, 2009, Wiesel, Fitzig, Herschman, & Messineo, 2009, Wiesel, Arbesfeld, & Schechter, 2014 and the feasibility of this device as a screening tool , Omboni & Verberk, 2016, Wiesel & Salomone, 2017.…”
Section: Oscillometrymentioning
confidence: 99%