2011
DOI: 10.1590/s0103-50532011001000011
|View full text |Cite
|
Sign up to set email alerts
|

Attenuated total reflectance with Fourier transform infrared spectroscopy (ATR/FTIR) and different PLS Algorithms for simultaneous determination of clavulanic acid and amoxicillin in powder pharmaceutical formulation

Abstract: Um método para determinação simultânea de ácido clavulânico (CA) e amoxicilina (AMO) foi desenvolvido utilizando a técnica de espectroscopia no infravermelho médio com transformada de Fourier acoplada ao acessório de reflexão total atenuada (ATR/FTIR). Utilizaram-se 27 e 8 amostras para os conjuntos de calibração e previsão, respectivamente. Os modelos de calibração foram desenvolvidos utilizando os algoritmos por mínimos quadrados parciais (PLS), PLS por intervalo (iPLS), PLS por sinergismo (siPLS) e PLS por … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
7

Year Published

2015
2015
2020
2020

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 35 publications
(14 citation statements)
references
References 16 publications
0
7
0
7
Order By: Relevance
“…The RMSECV was used to select the optimum number of LVs. [ 38,39 ] The RPD is the ratio of the standard deviation of the reference data in the validation set to the RMSEP; the higher the RPD, the better the model performs. [ 35 ] Generally, an RPD value higher than 3.0 indicates excellent prediction accuracy for analysis, and an RPD between 2.5 and 3.0 implies that the model is precise.…”
Section: Methodsmentioning
confidence: 99%
“…The RMSECV was used to select the optimum number of LVs. [ 38,39 ] The RPD is the ratio of the standard deviation of the reference data in the validation set to the RMSEP; the higher the RPD, the better the model performs. [ 35 ] Generally, an RPD value higher than 3.0 indicates excellent prediction accuracy for analysis, and an RPD between 2.5 and 3.0 implies that the model is precise.…”
Section: Methodsmentioning
confidence: 99%
“…Several analytical techniques have been applied for AMX and CLA determination in pharmaceutical and biological Abbreviations: AMX, amoxicillin; C 4 samples, such as HPLC [3][4][5][6], TLC with densitometric detection [7], UHPLC-MS/MS [8], CE with UV detection [9,10], MS [11], spectrophotometry [12,13], chemiluminescence [14], attenuated total reflectance with FTIR spectroscopy [15], sequential injection analysis [16][17][18], FIA [19], and stopped-flow techniques [20,21]. Most of the reported methods generally require expensive instrumentation and are time-consuming, which is undesirable in quality control activities.…”
Section: Introductionmentioning
confidence: 99%
“…Interval partial least-squares (iPLS), proposed by Nørgaard et al for interval selection, represents an approach for local regression modeling of spectral data [17]. Some extended algorithms of iPLS, such as forward iPLS (fiPLS) and backward iPLS (biPLS), have been developed and successfully applied [18][19][20]. However, iPLS, fiPLS, and biPLS have not been used in the determination of IV in fats and oils using FTIR data.…”
Section: Introductionmentioning
confidence: 99%