2021
DOI: 10.1016/j.ijpsycho.2021.07.503
|View full text |Cite
|
Sign up to set email alerts
|

Auto-QCLF: A Quick and Reliable EEG Lead Field Quality Control for Big Databases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…These results were subjected to visual quality control, obtaining 60 Lead Fields marked as doubtful and the rest as good. All 60 LFs declared as "doubtful," and another 40 goods LF samples from the 1251 LFs of the CMI dataset were used as the sample in the Automatic Quality Control of the numerical accuracy of EEG Lead Fields (LF-AQI) (Vega et al, 2021). This analysis found three main reasons why the LFs were screened as "doubtful": the first reason was the blurred/noisy in the MRI causing inaccurate segmentation, the second one was an evident misalignment of the Cortex inside the head, and the bad alignment of the sensor's layout caused thirst.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…These results were subjected to visual quality control, obtaining 60 Lead Fields marked as doubtful and the rest as good. All 60 LFs declared as "doubtful," and another 40 goods LF samples from the 1251 LFs of the CMI dataset were used as the sample in the Automatic Quality Control of the numerical accuracy of EEG Lead Fields (LF-AQI) (Vega et al, 2021). This analysis found three main reasons why the LFs were screened as "doubtful": the first reason was the blurred/noisy in the MRI causing inaccurate segmentation, the second one was an evident misalignment of the Cortex inside the head, and the bad alignment of the sensor's layout caused thirst.…”
Section: Discussionmentioning
confidence: 99%
“…Since we have already performed automatic sensor correction during the head modeling step, we manually correct the electrode alignment and placement on the scalp and recompute the Lead Field again after the manual correction and processed by the aftermanual-quality-control process. Once the corrections were completed, the LFs marked as bad were passed through the LF-AQI pipeline (Vega et al, 2021), getting all then corrected and declared as goods, and LF-AQI then accepted these LFs.…”
Section: Discussionmentioning
confidence: 99%
“…These artifact annotations follow a standard questionnaire prepared following the HCP quality control recommendations (Marcus et al, 2013). We conducted a final trial on the annotated artifacts, calculating their scores using item response theory (Vega et al, 2021;Riaz et al, 2023).…”
Section: Geometrical Artifact Correctionsmentioning
confidence: 99%