2016
DOI: 10.1111/sjos.12256
|View full text |Cite
|
Sign up to set email alerts
|

Autocovariance Estimation in Regression with a Discontinuous Signal and m‐Dependent Errors: A Difference‐Based Approach

Abstract: Abstract. We discuss a class of difference-based estimators for the autocovariance in nonparametric regression when the signal is discontinuous (change-point regression), possibly highly fluctuating, and the errors form a stationary m-dependent process. These estimators circumvent the explicit pre-estimation of the unknown regression function, a task which is particularly challenging for such signals. We provide explicit expressions for their mean squared errors when the signal function is piecewise constant (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
32
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 32 publications
(33 citation statements)
references
References 59 publications
(141 reference statements)
1
32
0
Order By: Relevance
“…Currents were digitized by a Digidata 1440A A/D converter and recorded using the software AxoScope 10.3 and Clampex 10.3 (all Molecular Devices). Analysis of the data was carried out using R-packages stepR ( Hotz et al, 2013 ) and dbacf ( Tecuapetla-Gómez and Munk, 2015 ) and OriginPro 8.5 (OriginLab, MA, USA). After incorporation of Tim23 into the lipid bilayer, symmetrical conditions were set by perfusion with 20x chamber volume of 250 mM KCl, 10 mM MOPS-Tris, pH 7.0.…”
Section: Methodsmentioning
confidence: 99%
“…Currents were digitized by a Digidata 1440A A/D converter and recorded using the software AxoScope 10.3 and Clampex 10.3 (all Molecular Devices). Analysis of the data was carried out using R-packages stepR ( Hotz et al, 2013 ) and dbacf ( Tecuapetla-Gómez and Munk, 2015 ) and OriginPro 8.5 (OriginLab, MA, USA). After incorporation of Tim23 into the lipid bilayer, symmetrical conditions were set by perfusion with 20x chamber volume of 250 mM KCl, 10 mM MOPS-Tris, pH 7.0.…”
Section: Methodsmentioning
confidence: 99%
“…Difference‐based estimators of σ 2 for this case were proposed in Müller and Stadtmüller (), Herrmann et al . () and Tecuapetla‐Gómez and Munk () among others. Presumably the most widely used error model in practice is an AR( p ) process.…”
Section: Estimation Of the Long‐run Error Variancementioning
confidence: 91%
“…We assume that the recordings result from equidistant sampling from the convolution of an unknown piecewise constant signal corrupted by Gaussian white noise with the (known) kernel of a lowpass filter. We stress however that our methodology can be extended to an unknown filter by using the methodology of [37]. To incorporate heterogeneity, the white noise is scaled by an unknown piecewise constant function to allow a larger variance on segments on which the conductance is larger.…”
Section: Modelingmentioning
confidence: 99%