2005
DOI: 10.1016/j.jchromb.2004.10.009
|View full text |Cite
|
Sign up to set email alerts
|

Automated 96-well solid phase extraction and hydrophilic interaction liquid chromatography–tandem mass spectrometric method for the analysis of cetirizine (ZYRTEC®) in human plasma—with emphasis on method ruggedness

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
47
0

Year Published

2007
2007
2016
2016

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 50 publications
(47 citation statements)
references
References 41 publications
0
47
0
Order By: Relevance
“…The UV detection has been the most common detector used for its simplicity and low cost, while the mass spectrometry has been less frequently applied due to the high instrumentation cost. The sample preparation procedure developed in this work, including single liquid-liquid extraction, was optimized to eliminate time-consuming purification steps (Choi et al, 2000a;Kim et al, 2005;Pandya et al, 1996), entailing a derivatization procedure (Baltes et al, 1988) and solid-phase extraction (Song et al, 2005), as used in previous work. Several earlier published works have described the assay of racemic cetirizine in biological samples.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The UV detection has been the most common detector used for its simplicity and low cost, while the mass spectrometry has been less frequently applied due to the high instrumentation cost. The sample preparation procedure developed in this work, including single liquid-liquid extraction, was optimized to eliminate time-consuming purification steps (Choi et al, 2000a;Kim et al, 2005;Pandya et al, 1996), entailing a derivatization procedure (Baltes et al, 1988) and solid-phase extraction (Song et al, 2005), as used in previous work. Several earlier published works have described the assay of racemic cetirizine in biological samples.…”
Section: Resultsmentioning
confidence: 99%
“…A high-performance liquid chromatography (HPLC) with ultraviolet detection (UV) is the most widely used technique (Macek et al, 1999;Choi et al, 2000a, b;Kim et al, 2005;Zaater et al, 2000;Moncrieff, 1992;Jelinska et al, 2000Jelinska et al, , 2001Paw et al, 2002;Arayne et al, 2005;Bajerski et al, 2005;El Walily et al, 1998;Jaber et al, 2004;Nagaralli et al, 2003;Likar et al, 2005;Rosseel and Lefebvre, 1991) or liquid chromatography with spectrometric detection (LC-MS/MS) (Gergov et al, 2001;Gupta et al, 2005;de Jager et al, 2002;Rudaz et al, 2003;Song et al, 2005;Tan et al, 2006). Previously published methods included also gas chromatography (GC) (Baltes et al, 1988), high-performance thin-layer chromatography (HPTLC) (Makhija and Vavia, 2001;Pandya et al, 1996), electrooxidation (Güngör, 2004), spectrophotometric (El Walily et al, 1998;Mahgoub et al, 2003;Gowda et al, 2001;Basavaiah and Charan, 2002;Basavaiah et al, 1999;Gazy et al, 2002), titrimetric technique (Basavaiah and Charan, 2002) for cetirizine determination and assay based on cetirizine-tetraphenylborate ion-pair analysis (Shoukry et al, 1999).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A new method was developed using direct injection of SPE extracts for the analysis of isoniazid 5 and cetirizine 6 by HILIC-ESI-MS/MS [90]. This method was then improved into a 96-well SPE format, which was also described by Kall et al [91], and finally, the whole system was upgraded to an automated 96-well SPE format [92] coupled with HILIC-ESI-MS/MS. The method eliminates the evaporation and reconstitution steps between the SPE and HILIC separation.…”
Section: Pharmacokineticsmentioning
confidence: 99%
“…In particular, an LLE direct injection determination of DNP is proposed for the first time. As for SPE analytical methods for CTZ determination, a protocol has been reported (Li et al, 2004b) employing a different SPE plate than the one involved in this method, while all other SPE methods do not employ direct injection techniques (Song et al, 2005;Erisken et al, 2002). Finally, PP plate combination with direct injection technique is also reported in the current study for the first time.…”
Section: Introductionmentioning
confidence: 99%