1997
DOI: 10.1016/s0002-9149(97)00673-5
|View full text |Cite
|
Sign up to set email alerts
|

Automated Assessment of Mitral Regurgitant Volume and Regurgitant Fraction by a Newly Developed Digital Color Doppler Velocity Profile Integration Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

1999
1999
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 12 publications
0
8
0
Order By: Relevance
“…[4][5][6][7][8][9][10] It has been reported that flow volume determined by the ACM algorithm shows good agreement with that measured by flowmeter in experimental studies. 4 Recent reports have shown good correlations between ACM and clinically accepted techniques such as the thermodilution method for estimating aortic outflow volume in the clinical situation.…”
Section: Estimation Of the Qp/qs Ratio By Acm Methodsmentioning
confidence: 58%
See 1 more Smart Citation
“…[4][5][6][7][8][9][10] It has been reported that flow volume determined by the ACM algorithm shows good agreement with that measured by flowmeter in experimental studies. 4 Recent reports have shown good correlations between ACM and clinically accepted techniques such as the thermodilution method for estimating aortic outflow volume in the clinical situation.…”
Section: Estimation Of the Qp/qs Ratio By Acm Methodsmentioning
confidence: 58%
“…The newly developed automated cardiac flow measurement (ACM) method, using spatial and temporal integration of colour Doppler velocity profiles, provides an accurate and quick automated flow volume measurement without the limitations inherent in pulsed Doppler echocardiography. [4][5][6][7][8][9] This new method has recently been validated for the calculation of the Qp/Qs ratio by measurement of both left and right ventricular stroke volumes in an animal study. 10 To our knowledge, however, there have been no reports of the application of ACM for determining the Qp/Qs ratio in patients with atrial septal defects.…”
mentioning
confidence: 99%
“…[16][17][18][19][20][21] Colour Doppler echocardiography was undertaken with a Toshiba SSA-380A ultrasound imaging system equipped with prototype ACM software and a 2.5 MHz transducer. Frame rate was set at 27 frames/s with a 30°colour sector.…”
Section: Acm Methodsmentioning
confidence: 99%
“…One of the two-dimensional techniques, the automated cardiac output measurement method, involves positioning a rectangular region of interest in the flow while scanning parallel to the direction of flow [28][29][30][31] . The velocities within the selected region are integrated on a frame to frame basis to compute spatial and temporal flow profiles and generate flow volume data.…”
Section: Other Digital Colour Doppler Techniquesmentioning
confidence: 99%