1992
DOI: 10.1007/bf00166760
|View full text |Cite
|
Sign up to set email alerts
|

Automated detection and quantification of microaneurysms in fluorescein angiograms

Abstract: Fluorescein angiograms from diabetics were digitised for analysis using digital image-processing techniques. Computer algorithms were written to detect and count microaneurysms present in the images. The accuracy, speed and reproducibility of the technique were assessed and compared with those of manual counts made by clinicians from both digitised and analogue images. Free-response ROC (receiver operating characteristic) curves were used to assess the performance of both the clinicians and the computer by com… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
61
0
3

Year Published

1996
1996
2014
2014

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 114 publications
(65 citation statements)
references
References 13 publications
1
61
0
3
Order By: Relevance
“…This performance is achieved with few manually annotated training samples. Moreover, the increased in performance obtained by using scale-adapted (variable σ) features against fixed scale approach asserts the importance of [7] Top-hat transform 12% 20.3 Abdelazeem [17] Circular Hough-transform 28% 505.85 Walter et al [10] Diameter closing 36% 154.42 Zhang et al [16] Multiple-Gaussian mask 33% 328.3 Lazar et al [14,15] Cross Table 4: FROC results on of retinopathy challenge testing dataset at low false positives per image.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…This performance is achieved with few manually annotated training samples. Moreover, the increased in performance obtained by using scale-adapted (variable σ) features against fixed scale approach asserts the importance of [7] Top-hat transform 12% 20.3 Abdelazeem [17] Circular Hough-transform 28% 505.85 Walter et al [10] Diameter closing 36% 154.42 Zhang et al [16] Multiple-Gaussian mask 33% 328.3 Lazar et al [14,15] Cross Table 4: FROC results on of retinopathy challenge testing dataset at low false positives per image.…”
Section: Resultsmentioning
confidence: 99%
“…Background estimation and subtraction methods are the most commonly used techniques to correct shading effects [7]. This method uses the green channel of the image to estimate the "background" image using a large median filter of size 25 × 25 and sub-tract it from the green channel resulting in the shade corrected image.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Aunque en los últimos años han surgido publicaciones sobre la detección automática de microaneurismas [3][4][5][6][7] , son pocas las que se centran en la detección en imágenes de retinografía [8][9][10][11] .…”
Section: Discussionunclassified
“…Un número importante de publicaciones en el campo de la ingeniería abordan este problema 2 . La mayoría de ellas se centra en la detección de MA en angiografías de fluoresceína [3][4][5][6][7] . Øien y Osnes fueron los primeros en detectar MA en imáge-nes en color 8 .…”
Section: Introductionunclassified