2016 IEEE Technological Innovations in ICT for Agriculture and Rural Development (TIAR) 2016
DOI: 10.1109/tiar.2016.7801217
|View full text |Cite
|
Sign up to set email alerts
|

Automated intravenous fluid monitoring and alerting system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
3

Year Published

2018
2018
2024
2024

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(16 citation statements)
references
References 1 publication
0
13
0
3
Order By: Relevance
“…The converter sends a signal to the microcontroller that activates the voice module (sound recording), alerting the medical staff. The coupling of the load cell for measuring the weight of the IV bag (through fluid level detection in the bag), and the sensor for measuring the patient's pulse, just before the cannula, is shown in [6]. If the bag empties or the patient's pulse is outside the allowed values, then the microcontroller sends an alarm to the receiver at the nurse room via the Zigbee module.…”
Section: Fluid Level Detection and Signaling Systems In IV Bottle/bagmentioning
confidence: 99%
See 1 more Smart Citation
“…The converter sends a signal to the microcontroller that activates the voice module (sound recording), alerting the medical staff. The coupling of the load cell for measuring the weight of the IV bag (through fluid level detection in the bag), and the sensor for measuring the patient's pulse, just before the cannula, is shown in [6]. If the bag empties or the patient's pulse is outside the allowed values, then the microcontroller sends an alarm to the receiver at the nurse room via the Zigbee module.…”
Section: Fluid Level Detection and Signaling Systems In IV Bottle/bagmentioning
confidence: 99%
“…The advantages of the described systems are continuous detection of IV bottle/bag fluid level [4][5][6][7][8][9][11][12][13][14], sound alarm in the patient's room [4][5][6]8,9,11,13,14], LCD for text alarms in the patient's room [4,6,9,11,13,14], alarm (sound, SMS or LCD) at the nurse room [6,7,9,12], and additional sensors for fluid level detection or monitoring of the patient's condition [6,9,12,14].…”
Section: Fluid Level Detection and Signaling Systems In IV Bottle/bagmentioning
confidence: 99%
“…A constituição do sistema mecânico do SPODi_Med foi feita empregando uma estrutura de tripé de fotografia, como base de fixação dos componentes do sensor e os descartáveis hospitalares (equipo e reservatório). A principal função do sistema mecânico é garantir a fixação do elemento do sensor sem ocorrência de deformações mecânicas na sua estrutura devido à aplicação da força peso do líquido contido no reservatório de medicamento, que pode variar o seu peso de acordo com o conteúdo da embalagem (tipicamente os volumes nominais mais empregados são: 50mL, 100mL, 250mL, 500mL e 1L [Bhavasaar et al 2016]).…”
Section: Sistema Mecânico Do Spodi_medunclassified
“…In recent years, several methods [1]- [16] have been developed to make the process of monitoring intravenous infusion easier both for the patients and clinicians. Although the overall purpose of these systems is to monitor the flow rate and raise a warning in case of any anomaly, the techniques used to develop these systems and the functionalities fulfilled by them are subject to considerable variation.…”
Section: Fig1 Techniques Used In Intravenous Infusion Monitoring Symentioning
confidence: 99%
“…This difference is directly proportional to the light intensity detected by the sensor, which when amplified aids in the detection of air-embolisms. [1].…”
Section: A Alarm-based Systemsmentioning
confidence: 99%