2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe) 2018
DOI: 10.1109/isgteurope.2018.8571427
|View full text |Cite
|
Sign up to set email alerts
|

Automated Quantification of PV Hosting Capacity In Distribution Networks Under User-Defined Control and Optimisation Procedures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(16 citation statements)
references
References 6 publications
0
16
0
Order By: Relevance
“…The HC is more pronounced in the LV systems with more midday loading as per the findings of this study. Moreover, the HC values of a three-phase four-wire unbalanced LV network in Perth, Australia, and radial test feeder in Switzerland was found to be as 63.81 kW (31.9%) and 43 kVA in [39] and [46], respectively. The researchers in [46] investigated the application of the user-defined control and application of the Smart Inverter control for the increase in HC and concluded that the appropriate adjustment of inverter control parameters results in larger HC improvement as compared to fixed parameters.…”
Section: Transformer Ratingmentioning
confidence: 97%
See 4 more Smart Citations
“…The HC is more pronounced in the LV systems with more midday loading as per the findings of this study. Moreover, the HC values of a three-phase four-wire unbalanced LV network in Perth, Australia, and radial test feeder in Switzerland was found to be as 63.81 kW (31.9%) and 43 kVA in [39] and [46], respectively. The researchers in [46] investigated the application of the user-defined control and application of the Smart Inverter control for the increase in HC and concluded that the appropriate adjustment of inverter control parameters results in larger HC improvement as compared to fixed parameters.…”
Section: Transformer Ratingmentioning
confidence: 97%
“…Moreover, the HC values of a three-phase four-wire unbalanced LV network in Perth, Australia, and radial test feeder in Switzerland was found to be as 63.81 kW (31.9%) and 43 kVA in [39] and [46], respectively. The researchers in [46] investigated the application of the user-defined control and application of the Smart Inverter control for the increase in HC and concluded that the appropriate adjustment of inverter control parameters results in larger HC improvement as compared to fixed parameters. A rural small farm that experiences large variations in local demand from zero to its rated value is analyzed for HC value with reference to the transformer rating in [13].…”
Section: Transformer Ratingmentioning
confidence: 97%
See 3 more Smart Citations