2005
DOI: 10.1016/j.ijoa.2005.05.004
|View full text |Cite
|
Sign up to set email alerts
|

Automated regular boluses for epidural analgesia: a comparison with continuous infusion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

6
65
1
1

Year Published

2010
2010
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 87 publications
(73 citation statements)
references
References 14 publications
6
65
1
1
Order By: Relevance
“…During the first three hours, median sensory block height to cold was higher and serial pain scores were lower among patients given intermittent boluses. Lim et al 5 demonstrated a reduced incidence of breakthrough pain requiring anesthesiologist-administered top-up when epidural analgesia was maintained using intermittent boluses of 5 mL every half hour as compared to a continuous infusion of 10 mL/h following induction of analgesia with intrathecal fentanyl 25 lg. However, unlike earlier studies, parturients in our current trial were able to supplement the degree of analgesia to their desired level using the PCEA.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…During the first three hours, median sensory block height to cold was higher and serial pain scores were lower among patients given intermittent boluses. Lim et al 5 demonstrated a reduced incidence of breakthrough pain requiring anesthesiologist-administered top-up when epidural analgesia was maintained using intermittent boluses of 5 mL every half hour as compared to a continuous infusion of 10 mL/h following induction of analgesia with intrathecal fentanyl 25 lg. However, unlike earlier studies, parturients in our current trial were able to supplement the degree of analgesia to their desired level using the PCEA.…”
Section: Discussionmentioning
confidence: 99%
“…3 Earlier studies have suggested that regular intermittent epidural boluses, as compared to a continuous epidural infusion, increase maternal satisfaction and decrease the incidence of breakthrough pain during the maintenance of labor epidural analgesia. [4][5][6] This may be attributed to a more extensive spread of epidural solution when delivered as a bolus rather than continuous infusion. 7 When incorporated into a PCEA regimen and used in place of a continuous basal infusion, automated intermittent boluses have been observed to reduce overall local anesthetic consumption without compromising analgesic efficacy.…”
Section: Introductionmentioning
confidence: 99%
“…It has been documented that PIEB is associated with less need for clinician intervention for inadequate pain control. There has been observed an increase in time to the first rescue bolus (5-7, 9, 10) and a lower number of manual boluses (5,11,12) in several studies. This has impact for both the parturient and the anesthesia work load.…”
mentioning
confidence: 98%
“…PIEB has gained considerable attention for the ability to improve patient satisfaction with their labor experience (6,11). The systematic review identified greater maternal satisfaction in the PIEB groups when evaluated by using a verbal rating scale (VRS) (4).…”
mentioning
confidence: 99%
“…20 Lim et al found lower incidence of breakthrough pain and higher maternal satisfaction in patients using automated regular bolus delivery of epidural analgesia when compared to continuous infusion. 21 Patient or physician controlled intermittent injections increases the workload compared to continuous infusion technique. We used intermittent epidural injection technique in our obstetric unit.…”
Section: Group 1 Group 2 Pmentioning
confidence: 99%