2021
DOI: 10.1016/j.jneumeth.2021.109267
|View full text |Cite
|
Sign up to set email alerts
|

Automated segmentation of choroidal layers from 3-dimensional macular optical coherence tomography scans

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 32 publications
1
3
0
Order By: Relevance
“…The average ChT in the test dataset composed of images with HM was 75.9±34.4 μm. As expected, the ChT was thinner than that reported in previous studies, as they had tended to focus on non-HM participants (38,39). By analyzing the difference of ICCs in the 9 regions, the ChT calculated in the outer nasal region was less consistent with the manual.…”
Section: Discussionsupporting
confidence: 40%
See 1 more Smart Citation
“…The average ChT in the test dataset composed of images with HM was 75.9±34.4 μm. As expected, the ChT was thinner than that reported in previous studies, as they had tended to focus on non-HM participants (38,39). By analyzing the difference of ICCs in the 9 regions, the ChT calculated in the outer nasal region was less consistent with the manual.…”
Section: Discussionsupporting
confidence: 40%
“…There are some studies that included the quantification of retinal features and ChT in AMD eyes (32)(33)(34), investigations on optic disc changes and their association with ChT in young myopic patients (35), and the use of algorithms to determine changes in ChT and volume of choroidal vessels (34,36,37). However, previous studies of automated ChT calculations were designed based on mostly non-HM eyes (38)(39)(40). Automated identification and calculation of ChT in HM eyes still warrant further study, and our team has research experience in this field (30,41).…”
Section: Discussionmentioning
confidence: 99%
“…Deep learning approaches have achieved great success in OCT image segmentation tasks [19], [25], [32], [36], [41], [43], [48]. [47] developed a fully convolutional network with Gaussian process based post processing for retinal OCT segmentation.…”
Section: Related Workmentioning
confidence: 99%
“…[8][9][10][11] Several studies have analyzed the choroid layer using the B-scan image of OCT and arti cial intelligence. [22][23][24][25][26][27][28][29] However, OCT B-scan image shows a cross-sectional view of blood vessels at the one scan position. On the other hand, the en face OCT image, also known as C-scan image, provides a two-dimensional and plane view of the choroidal blood vessels in the scanned area.…”
Section: Introductionmentioning
confidence: 99%