2021
DOI: 10.1186/s41181-021-00120-5
|View full text |Cite
|
Sign up to set email alerts
|

Automated synthesis of [18F]Ga-rhPSMA-7/ -7.3: results, quality control and experience from more than 200 routine productions

Abstract: Introduction The radiohybrid (rh) prostate-specific membrane antigen (PSMA)-targeted ligand [18F]Ga-rhPSMA-7 has previously been clinically assessed and demonstrated promising results for PET-imaging of prostate cancer. The ligand is present as a mixture of four stereoisomers ([18F]Ga-rhPSMA-7.1, − 7.2, − 7.3 and − 7.4) and after a preclinical isomer selection process, [18F]Ga-rhPSMA-7.3 has entered formal clinical trials. Here we report on the establishment of a fully automated production proc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0
2

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 17 publications
(15 citation statements)
references
References 33 publications
0
13
0
2
Order By: Relevance
“…In 2019, Wester et al published their important work regarding the production of radiohybrid prostate-specific membrane antigen (rhPSMA) inhibitors, constituting a great contribution to the field of medical imaging, as well as therapeutics [ 32 ]. These radiotracers incorporate both a SiFA BB and a metal chelator.…”
Section: Peptidesmentioning
confidence: 99%
See 3 more Smart Citations
“…In 2019, Wester et al published their important work regarding the production of radiohybrid prostate-specific membrane antigen (rhPSMA) inhibitors, constituting a great contribution to the field of medical imaging, as well as therapeutics [ 32 ]. These radiotracers incorporate both a SiFA BB and a metal chelator.…”
Section: Peptidesmentioning
confidence: 99%
“…These results further validate its potential as an imaging agent, although further studies are required to determine its efficacy as a theranostic agent in combination with the radiometal 177 Lu. Importantly, due to its favorable outcome, 18 F-synthesis has been fully automated using the Munich Method, which is perfectly suited for SiFA IE [ 32 ]. This allows for the synthesis to occur with extremely high reliability (98.8%), meaning the production procedure was successful for 240/243 runs resulting in an average RCY and RCP of 50% and 99.9%, respectively [ 32 ].…”
Section: Peptidesmentioning
confidence: 99%
See 2 more Smart Citations
“…Before DE-SRT, each patient received PET imaging with [68Ga] PSMA-11 (8) or a [18F]-labeled PSMA-ligand ([18F]PSMA-1007 ( 9), [18F]rhPSMA-7 (10), or [18F]rhPSMA-7.3 (11)). PET acquisition was performed according to the joint EANM and SNMMI guidelines (12).…”
Section: Psma-pet Imagingmentioning
confidence: 99%