Automatic Generation of a Plan Optimization Volume for Tangential Field Breast Cancer Radiation Therapy

Abstract: This automated planning method is capable of replacing the contouring of the clinical target volume as well as the trial-and-error procedure of assigning weights of wedged and unwedged beams by an experienced planner.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2008
2008
2013
2013

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 17 publications
0
4
0
Order By: Relevance
“…Because of the shortness of manually indicated contour parts the PTV differences might decrease. A comparable method was developed by van Vaerenbergh et al [39], with "plan optimization volume" simulation, breast tissue being overlapped by two tangents and an orthogonal field.…”
Section: Discussionmentioning
confidence: 99%
“…Because of the shortness of manually indicated contour parts the PTV differences might decrease. A comparable method was developed by van Vaerenbergh et al [39], with "plan optimization volume" simulation, breast tissue being overlapped by two tangents and an orthogonal field.…”
Section: Discussionmentioning
confidence: 99%
“…Various methods have been used in the past to delineate the breast CTV: anatomic references have been used as a guide [ 10 , 11 ], but also radiopaque wires marking the palpable breast [ 6 , 12 ]. In some studies, a conventional beam set-up was used even when CT data were available [ 13 , 14 ]. In these studies, CT data were used for dose calculation and evaluation of the dose to organs at risk, while the breast CTV was not explicitly defined.…”
Section: Discussionmentioning
confidence: 99%
“…Gantry angles expressed in the Elekta coordinate system. The most inclined medial beam has the gantry angle of a tangential beam set by virtual simulation [21]. The gantry angles are 0°, |α|, |2α|, 180° - 0.5|α|, 180° + 0.5|α|, and 180° + 1.5|α| for supine MB-IMRT.…”
Section: Methodsmentioning
confidence: 99%
“…The convolution-superposition dose engine of a Pinnacle version 9.0 treatment planning system (Philips Medical Systems, Andover, US) was used for dose computations between optimization cycles of intensity-modulated plans as well as for final plans. Monitor units and MLC shapes were optimized using the optimization tools described before [21]. During optimization, two patient geometries were taken into account: 1) dose computation for PTV WBI was performed using a density override (1 g/cm 3 ) to the above-mentioned flash region; 2) dose computation for the PTV WBI without build-up and OARs was performed without density overrides.…”
Section: Methodsmentioning
confidence: 99%