2011
DOI: 10.1007/s00259-011-1730-3
|View full text |Cite
|
Sign up to set email alerts
|

Automatic generation of absolute myocardial blood flow images using [15O]H2O and a clinical PET/CT scanner

Abstract: PurposeParametric imaging of absolute myocardial blood flow (MBF) using [15O]H2O enables determination of MBF with high spatial resolution. The aim of this study was to develop a method for generating reproducible, high-quality and quantitative parametric MBF images with minimal user intervention.MethodsNineteen patients referred for evaluation of MBF underwent rest and adenosine stress [15O]H2O positron emission tomography (PET) scans. Ascending aorta and right ventricular (RV) cavity volumes of interest (VOI… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
103
0
1

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
2

Relationship

4
4

Authors

Journals

citations
Cited by 142 publications
(105 citation statements)
references
References 19 publications
1
103
0
1
Order By: Relevance
“…Dynamic data sets were analyzed using the software package Cardiac VUer, as previously described 18. Image‐derived arterial input function was obtained automatically and corrected for metabolites 18, 19.…”
Section: Methodsmentioning
confidence: 99%
“…Dynamic data sets were analyzed using the software package Cardiac VUer, as previously described 18. Image‐derived arterial input function was obtained automatically and corrected for metabolites 18, 19.…”
Section: Methodsmentioning
confidence: 99%
“…0.75, V A or V RV . 0.60, or anatomic tissue fraction , 0.25, MBF, K 1 , and V T were set to zero to avoid spurious noise-induced high values outside the heart or in blood vessels as described previously (20,29). Finally, MBF T images were obtained by multiplying MBF images by PTF images.…”
Section: Parametric Imagesmentioning
confidence: 99%
“…Input functions were obtained using in-house-developed software, Cardiac VUer (20,21). For both 15 O-water and 11 C-HED, 1-cm-diameter regions of interest were placed over the ascending aorta in at least 5 transaxial image planes in the frame showing the first pass of the injected bolus.…”
Section: Input Functionsmentioning
confidence: 99%
See 1 more Smart Citation
“…Until recently, quantification of myocardial perfusion was primarily regarded as a research tool because it involved elaborate and time-consuming postprocessing procedures. Advances in PET systems have overcome these limitations and commercially available software packages currently generate quantitative MBF images in the order of minutes with high reproducibility [3]. As a consequence, absolute quantification of flow has ushered into the clinical arena.…”