2018
DOI: 10.1101/433284
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Automatic local resolution-based sharpening of cryo-EM maps

Abstract: Recent technological advances and computational developments, have allowed the reconstruction of cryo-EM maps at near-atomic resolution structures. Cryo-EM maps benefit significantly of a "postprocessing" step, normally referred to as "sharpening", that tends to increase signal at medium/high resolution. Here, we propose a new method for local sharpening of volumes generated by cryo-EM. The algorithm (LocalDeblur) is based on a local resolution-guided Wiener restoration approach, does not need any prior atomic… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 21 publications
(16 citation statements)
references
References 25 publications
0
16
0
Order By: Relevance
“…Extracted particles were imported into cryoSPARC v2.12.4 (15) for 2D classification, 3D 159 classification and non-uniform 3D refinement. The C1 RBD "up" reconstruction was sharpened 160 in cryoSPARC, and the 3D reconstruction with C3 symmetry was subjected to local B-factor 161 sharpening using LocalDeBlur (33). Models were built in Coot, before being iteratively refined 162 in both Phenix and ISOLDE (34)(35)(36).…”
Section: Cryo-em Data Processing 157mentioning
confidence: 99%
“…Extracted particles were imported into cryoSPARC v2.12.4 (15) for 2D classification, 3D 159 classification and non-uniform 3D refinement. The C1 RBD "up" reconstruction was sharpened 160 in cryoSPARC, and the 3D reconstruction with C3 symmetry was subjected to local B-factor 161 sharpening using LocalDeBlur (33). Models were built in Coot, before being iteratively refined 162 in both Phenix and ISOLDE (34)(35)(36).…”
Section: Cryo-em Data Processing 157mentioning
confidence: 99%
“…Often times, especially for large assemblies, some of the most interesting biology occurs in the outer segments of a map, whereby auxiliary (often sub-stoichiometrically occupied) components or associated protein factors relay a signal to the catalytic core (190). The proper way to interpret such structural cascades is through a careful assessment of local resolution and of locally filtered maps (188,191). Local resolution…”
Section: Cryo-em Map and Atomic Model Validationmentioning
confidence: 99%
“…Using Relion post-processing, we were able to determine the overall reconstruction resolution to be 4 Å ( Figure S1). Local resolution was determined using the corresponding Relion tool and local sharpening was done using LocalDeblur 37 . Over-sharpening was seen in last iterations of local sharpening.…”
Section: Image Processingmentioning
confidence: 99%