2018
DOI: 10.1016/j.bios.2018.03.018
|View full text |Cite
|
Sign up to set email alerts
|

Automatic smartphone-based microfluidic biosensor system at the point of care

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
128
0
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 235 publications
(130 citation statements)
references
References 75 publications
0
128
0
2
Order By: Relevance
“…While bipolar electrodes (BPEs) have been applied to many sensing motifs, their sensitivity and specificity are limited by the lack of diversity in voltammetric methods that have been developed for these wireless electrodes. In this study, electrochemiluminescence (ECL) from the co-oxidation of Ru(bpy) 3 2 + and tripropylamine (TPA) is evaluated as a reporting reaction for alternating current voltammetry (ACV) on a BPE at frequencies of 1.0 Hz and 5.0 Hz. We observe sinusoidal alternating luminescence that follows a similar trend to that of the simultaneously monitored current -a plot of the amplitude versus potential approximates a bellshaped curve.…”
Section: Alternating Current Voltammetry At a Bipolar Electrode With mentioning
confidence: 99%
See 4 more Smart Citations
“…While bipolar electrodes (BPEs) have been applied to many sensing motifs, their sensitivity and specificity are limited by the lack of diversity in voltammetric methods that have been developed for these wireless electrodes. In this study, electrochemiluminescence (ECL) from the co-oxidation of Ru(bpy) 3 2 + and tripropylamine (TPA) is evaluated as a reporting reaction for alternating current voltammetry (ACV) on a BPE at frequencies of 1.0 Hz and 5.0 Hz. We observe sinusoidal alternating luminescence that follows a similar trend to that of the simultaneously monitored current -a plot of the amplitude versus potential approximates a bellshaped curve.…”
Section: Alternating Current Voltammetry At a Bipolar Electrode With mentioning
confidence: 99%
“…[2] A growing body of work is dedicated to adapting smartphones as PON tools because of their low cost, portability, and accessibility. [3][4][5][6][7][8][9] Detection of colorimetric, [5] fluorescent, [5] electrochromic, [4] and luminescent [6][7][8][9] signals with a smartphone have been demonstrated, and there are several examples of smartphone detection of reporting reactions on BPEs in the literature. [7,9] However, some of the most sensitive and information-rich voltammetric methods employ an alternating sinusoidal or square-wave potential, which are currently not developed for BPEs.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations