2015
DOI: 10.1080/00221686.2014.989459
|View full text |Cite
|
Sign up to set email alerts
|

Automatic swirl angle measurements for pump intake design

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 2 publications
0
6
0
Order By: Relevance
“…When the asymmetric velocity distribution or swirl flow arises from the intake upstream, the pump’s performance may be significantly affected. 25…”
Section: Intake Performance Evaluation Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…When the asymmetric velocity distribution or swirl flow arises from the intake upstream, the pump’s performance may be significantly affected. 25…”
Section: Intake Performance Evaluation Methodsmentioning
confidence: 99%
“…When the asymmetric velocity distribution or swirl flow arises from the intake upstream, the pump's performance may be significantly affected. 25 To evaluate the performance of the intake, the distribution of the axial velocity and swirl flow at intake outlet are investigated. The axial velocity distribution is evaluated by the uniformity and the weighted average angle of the axial velocity at the intake outlet, which are expressed as follows.…”
Section: Quantification Of Outflow Velocity Distribution and Hydrauli...mentioning
confidence: 99%
“…This large range in swirl angles is related to the stability of the flow patterns near the pump. De Fockert et al ( [2]) showed that for a pump compartment including splitte rs the range in swirl angle is m uch lowe r than for an em pty pum p com partment. In our investigation, large swirl angles up to 16° were created.…”
Section: Discussionmentioning
confidence: 99%
“…Swirl is measured by means of 4 magnets on the vanes of a low friction Perspex swirl meter, which are tracked by 3 sensors on the outer tube. This measurement method, including the obtained accuracy is extensively described in De Fockert et al ( [2]). …”
Section: Model Pumpmentioning
confidence: 99%
“…CFD analysis previously carried out on intake structure was mainly focused on the optimization of pump-sump design [5][6][7][8], the analysis of the internal flow patterns and what measures shall be taken to reduce the swirl flow and vortex, and the effect comparison between different measures and their combinations [9][10][11][12], but few of them were related to the prediction of flow condition of pump and the calculation of hydraulic loss of sump at different intake water levels. There were plenty of numerical simulations on outflow structure; however, it was rare to study the performance of pumping system through calculation of hydraulic loss and combined with the pump performance.…”
Section: Introductionmentioning
confidence: 99%