1999
DOI: 10.1002/(sici)1521-4109(199905)11:5<349::aid-elan349>3.0.co;2-0
|View full text |Cite
|
Sign up to set email alerts
|

Automatic Target Location Strategy-A Novel Approach in Scanning Electrochemical Microscopy

Abstract: In this article a recently constructed scanning electrochemical microscope with an original automatic target location facility is described and its operation is demonstrated on different targets. The measuring tip positioning device is based on stepper motor driven linear modules with 75 nm linear travel resolution. The home-built electronic unit and the Windows 95 compatible measuring and image-forming program furnish the microscope to operate in both amperometric and potentiometric modes. A novel, simplex al… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2003
2003
2013
2013

Publication Types

Select...
9

Relationship

5
4

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 22 publications
0
5
0
Order By: Relevance
“…A home-built SECM system was employed [17], using a 3D positioning device driven by precision step motors with 75 nm minimal step size. A video camera was used to further assist positioning of the tip close to the surface.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A home-built SECM system was employed [17], using a 3D positioning device driven by precision step motors with 75 nm minimal step size. A video camera was used to further assist positioning of the tip close to the surface.…”
Section: Methodsmentioning
confidence: 99%
“…The electric potential of this material changes in response to variations in the acidity of the environment due to its tendency to be coated by a Sb2O3 film. Thus, antimony tips have been employed as pH sensor in SECM for the characterization of a variety of systems [17][18][19], as well as microsensors for other techniques [20][21][22][23][24][25][26][27][28]. Due to the metallic properties of antimony, tips from this material can also be employed in amperometric SECM to image the topography of the substrates under investigation [16,18], thus allowing more information to be gained from these systems.…”
Section: Introductionmentioning
confidence: 99%
“…The SECM instrument has been described previously [47]. Main components are a 3D positioning stage driven by stepper motors (MFN 25PP; Newport, Irvine, CA, USA), a battery-powered voltage follower based on an operational amplifier (TL082;…”
Section: Instrumentationmentioning
confidence: 99%
“…A detailed description has already been published previously [17]. A short summary is only given here.…”
Section: Instrumentationmentioning
confidence: 99%