Autonomous Optimization Control and the Controllor for Pendulor

Abstract: A wave power converter: Pendulor, works with 40% efficiency at an optimal condition. Irrespective of change the wave climate, an Autonomous Optimization Control (AOC) adjusts hydrostatic power transmission to keep the Pendulor in the best match with the waves. This is a new system to know the wave climate from the Pendulor motion. AOC improves the system reliability and solves load sharing problem in the HST lines.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2016
2016
2016
2016

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Figure 15c shows the T p variation with H s when maximum C f is attained at T e = 12 s. As the T p and H s are almost linearly proportional, the device can operate even at higher efficiencies by utilising a proportional controller. This can be practically implemented as suggested by Watabe et al [37]. Figure 16b shows the cumulative energy capture for a 1500 s period for the same, demonstrating that the maximum energy is yielded when the load torque is at 0.8T p 0 .…”
Section: The Case Of Irregular Wavesmentioning
confidence: 78%
See 2 more Smart Citations
“…Figure 15c shows the T p variation with H s when maximum C f is attained at T e = 12 s. As the T p and H s are almost linearly proportional, the device can operate even at higher efficiencies by utilising a proportional controller. This can be practically implemented as suggested by Watabe et al [37]. Figure 16b shows the cumulative energy capture for a 1500 s period for the same, demonstrating that the maximum energy is yielded when the load torque is at 0.8T p 0 .…”
Section: The Case Of Irregular Wavesmentioning
confidence: 78%
“…The designed system was simulated as such in the irregular wave environment and fairly broader C f above 0.5 were obtained (refer Figure 18a). In this study, the features of the load torque T p that are implicitly dependent on the HST system loaded with the accumulator pressure/flow control systems [23,37] have not been considered. Therefore, to further enhance the energy yield, the only available controllable parameter is the load torque according to the model proposed.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation