2022
DOI: 10.1007/s00202-022-01602-8
|View full text |Cite
|
Sign up to set email alerts
|

Autonomous transient power management strategy based on improved droop control for DC microgrid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 31 publications
0
3
0
Order By: Relevance
“…Pokharel mainly solves the problems of intermittent and slow dynamic response in microgrids, and proposes a vertical control strategy based on DC bus signal. The effectiveness of the method has been verified through simulation [2]. Singh proposed a new power management strategy for power sharing between batteries and supercapacitors in energy storage systems, which is used to improve the efficiency of microgrid operation and has reference significance for the control of DC microgrids.…”
Section: Related Workmentioning
confidence: 99%
“…Pokharel mainly solves the problems of intermittent and slow dynamic response in microgrids, and proposes a vertical control strategy based on DC bus signal. The effectiveness of the method has been verified through simulation [2]. Singh proposed a new power management strategy for power sharing between batteries and supercapacitors in energy storage systems, which is used to improve the efficiency of microgrid operation and has reference significance for the control of DC microgrids.…”
Section: Related Workmentioning
confidence: 99%
“…Among these, droop control adjusts the relationship between the DC voltage and current through negative slope characteristics to realize the real-time control of the system power balance, which is a differential regulation. It has been widely used in DC distribution networks [5][6][7]. However, the line impedance impacts the droop coefficient, which will affect the output voltage of each converter station and the reasonable sharing of the system's load current among them [8].…”
Section: Introductionmentioning
confidence: 99%
“…Following is the suggested approach to charging for BESSs, i.e., steady current/consistent voltage (CC/CV) charging, the ordinary strategies go through mode exchanging utilizing a floating reference worth to control CV charging which doesn't ensure zero current when the battery is completely energized [12][13][14][15].…”
mentioning
confidence: 99%