2016 IEEE International Conference on Electronics, Circuits and Systems (ICECS) 2016
DOI: 10.1109/icecs.2016.7841165
|View full text |Cite
|
Sign up to set email alerts
|

Auxiliary power supply for solid state transformers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 8 publications
0
7
0
Order By: Relevance
“…Recent studies such as [17] and [18] tackle the start-up procedure by focusing on the energization issue based on the use of auxiliary power units (APUs). In all these studies, parameter and/or voltage imbalance conditions during the startup procedure are not considered and, in conclusion, it is recognized that the fundamental task in the start-up procedure is operated by the AC/DC power stage more than the DC/DC power stage.…”
Section: Introductionmentioning
confidence: 99%
“…Recent studies such as [17] and [18] tackle the start-up procedure by focusing on the energization issue based on the use of auxiliary power units (APUs). In all these studies, parameter and/or voltage imbalance conditions during the startup procedure are not considered and, in conclusion, it is recognized that the fundamental task in the start-up procedure is operated by the AC/DC power stage more than the DC/DC power stage.…”
Section: Introductionmentioning
confidence: 99%
“…This further increase cost and isolation concerns.  Redundancy intrinsic to the modular design will be compromised if a central APS with multiple outputs is used [17].…”
Section: A Apss Fed From Ac Portsmentioning
confidence: 99%
“…The use of a single APS to feed both HV and LV sides cell circuitry is possible. However, this solution is much more problematic, as it requires a bulky isolation stage, and energization from both sides is not possible without additional start-up circuitry [17].…”
Section: B Apss Fed From Dc-linksmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to reduce the transients at the instant of the SST connection to the MV grid, charging of the MV DC link (22 kV) from the LV port is proposed. Regarding supplying the auxiliary electronics, in [20], strategies for implementing an Auxiliary Power Supply (APS) for a modular three-stage SST and a process to start it up are discussed. The work focuses on the design and the validation of the proposed APS but no simulation or experimental results of the start-up procedure are provided.…”
Section: Introductionmentioning
confidence: 99%