2014
DOI: 10.1590/s0100-40422014000100002
|View full text |Cite
|
Sign up to set email alerts
|

Avaliação da mineralização de arroz em sistema de refluxo para a determinação de Cu, Fe, Mn e Zn por FAAS

Abstract: , Fe, Mn AND Zn BY FAAS. This paper describes the evaluation of a new method of sample preparation using a cold finger system with continuous water flow for rice analysis by flame atomic absorption spectrometry. The limits of detection for Cu, Fe, Mn and Zn for the proposed method were 0.36, 1.84, 2.12 and 0.16 mg kg -1 , respectively. The RSDs were lower than 6.0% for all elements and the CRM analyzed showed values with 95% agreement. The proposed method is simple and safe for the proposed objective and does … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(2 citation statements)
references
References 9 publications
0
1
0
1
Order By: Relevance
“…Recently, there have been reports of the use of reflux systems for acid decomposition in open systems, obtaining satisfactory results for the determination of several elements (including volatiles) in various kinds of samples (Ferreira et al 2013;Pinheiro et al 2014;Oreste et al 2013a;Oreste et al 2013b). The reflux system consists of a cold finger inserted in a digestion vessel for sample preparation using an open system with conventional heating.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, there have been reports of the use of reflux systems for acid decomposition in open systems, obtaining satisfactory results for the determination of several elements (including volatiles) in various kinds of samples (Ferreira et al 2013;Pinheiro et al 2014;Oreste et al 2013a;Oreste et al 2013b). The reflux system consists of a cold finger inserted in a digestion vessel for sample preparation using an open system with conventional heating.…”
Section: Introductionmentioning
confidence: 99%
“…Posteriormente, foram aquecidas sobre o bloco aquecedor (Tecnal TE40-05) a 150°C durante aproximadamente 4 horas. Para validação do método, as amostras foram digeridas em duplicata e, juntamente com as amostras, foram digeridas também: i) duplicatas do branco do método (10 mL de água ultra-pura com 3 mL de água régia processada exatamente como a amostra, incluindo exposição a todo equipamento, vidraria, procedimentos e reagentes), ii) o branco fortificado (branco do método contendo todos os reagentes como as amostras, no qual uma concentração conhecida dos analitos é adicionada) e iii) a amostra fortificada (10 mL de uma amostra na qual, antes do seu processamento, são adicionadas quantidades conhecidas dos analitos de interesse)(PINHEIRO, 2014; KRUG e ROCHA, 2016;PEREIRA et al, 2018).A digestão das amostras e as análises dos elementares foram realizadas no Instituto de Geociências e Ciências Exatas (IGCE/UNESP, Rio Claro-SP). Durante a digestão agitaram-se os tubos de vidro para observar a evolução dos estágios da digestão ácida, o branqueamento indicou o consumo da matéria orgânica e ocorreu redução do volume nos tubos de vidro (Figura 1).…”
unclassified