1986
DOI: 10.1136/jnnp.49.6.677
|View full text |Cite
|
Sign up to set email alerts
|

Axonal stimulation for end-plate jitter studies.

Abstract: SUMMARY This single fibre EMG study compares the standard method of neuromuscular jitter measurement in voluntarily activated muscle to that by intramuscular electrical stimulation of motor axons in a group of normal subjects. The latter method avoids the interdischarge intervaldependent jitter, as well as a possible failure to recognise split muscle fibres. The mean MCD on axonal stimulation was only 5-2 ps less than in the voluntary activation study and was thus 8% more than theoretically expected for single… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
54
1
8

Year Published

1989
1989
2008
2008

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 114 publications
(65 citation statements)
references
References 4 publications
2
54
1
8
Order By: Relevance
“…This variability may be in the time between APs of two fibres of the same motor unit in voluntary activity (Stalberg & Trontelj, 1979), or in the time between stimuli and APs in a fibre during a train of evoked responses (Trontelj et al, 1986). Excessive jitter is found in patients with muscular dystrophy or with myasthenia gravis, or after drugs (e.g.…”
Section: Introductionmentioning
confidence: 99%
“…This variability may be in the time between APs of two fibres of the same motor unit in voluntary activity (Stalberg & Trontelj, 1979), or in the time between stimuli and APs in a fibre during a train of evoked responses (Trontelj et al, 1986). Excessive jitter is found in patients with muscular dystrophy or with myasthenia gravis, or after drugs (e.g.…”
Section: Introductionmentioning
confidence: 99%
“…To get around this problem they devised a technique in which the most distal motor nerve fibres could be stimulated in the muscle and the muscle fibre potentials recorded with the standard needle used for SFEMG. [21][22][23][24] The stimulation is effected by a monopolar needle acting as the active electrode, sometimes with another as the indifferent electrode but more commonly with a surface electrode fulfilling that role. Although the application of the technique in the intensive care unit might have been the stimulus to its invention, its obvious advantages in the investigation of children were quickly realized.…”
Section: Stimulation Single-fibre Emgmentioning
confidence: 99%
“…Essa diferença é menor do que em comparações similares com a AFU (Trontelj et al, 1986) e, provavelmente, reflete as dificuldades técnicas de registros com a AC, por causa do registro de PAs somados e valores subestimados de jitter (Kouyoumdjian, Stålberg, 2008b).…”
Section: Técnicas De Análise Do Jitter E Critérios De Anormalidadeunclassified
“…O tempo de transmissão no trajeto do axônio e ao longo da fibra muscular possui um jitter combinado menor do que 4μs ("jitter miogênico") . Na fibra muscular, a velocidade de propagação varia levemente em impulsos consecutivos, e depende do intervalo de descarga do impulso precedente (IDI -interdischarge interval ou intervalo entre descarga) (Stålberg, 1966 (Trontelj et al, 1986). Se a medida do jitter for realizada em frequências irregulares de descargas, a VRF contribuirá significativamente para o aumento do valor do jitter.…”
Section: Introductionunclassified
See 1 more Smart Citation