Bacterial and corrosion resistance of polytetrafluoroethylene-silver composite coatings by magnetron sputtering
Haiwen Li,
Zhiwen He,
Wei Wu
et al.
Abstract:Titanium alloy and stainless steel implants have been widely applied in orthopedics. However, harmful ions released from implant corrosion caused by human body fluids and bacterial infections may inhibit patients’ recovery. In this work, a polytetrafluoroethylene-silver composite coating was prepared by RF unbalanced magnetron sputtering to improve the bacterial and corrosion resistance of the SS316L. The removal rates of the composite coatings for Escherichia coli and Staphylococcus aureus reached 97.27% and … Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.