2017
DOI: 10.21008/j.1897-0737.2017.92.0015
|View full text |Cite
|
Sign up to set email alerts
|

Badanie zmian parametrów eksploatacyjnych wybranych lamp do użytku domowego

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
1

Year Published

2018
2018
2018
2018

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 0 publications
0
4
0
1
Order By: Relevance
“…Nevertheless, they confirmed the need to constantly monitor products on the market, and particularly to carry out tests after 6000 h in order to fully assess the quality of LED lamps. As the tests have shown, even though all the lamps met the criterion of the minimum initial value of the luminous flux [8], only half of them had a luminous flux maintenance coefficient higher than the required one [1]. The tests carried out also allowed to calculate the expected life of lamps based on the initial 6000 h of lamp operation and evaluation of the procedure described in the publication [7].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Nevertheless, they confirmed the need to constantly monitor products on the market, and particularly to carry out tests after 6000 h in order to fully assess the quality of LED lamps. As the tests have shown, even though all the lamps met the criterion of the minimum initial value of the luminous flux [8], only half of them had a luminous flux maintenance coefficient higher than the required one [1]. The tests carried out also allowed to calculate the expected life of lamps based on the initial 6000 h of lamp operation and evaluation of the procedure described in the publication [7].…”
Section: Discussionmentioning
confidence: 99%
“…Six lamps from different manufacturers were selected for the tests. The basic information available on the packaging of the product as well as the results of measurements of the initial parameters of the tested LED lamps are described in the publication [8]. The appearance of the tested lamps is shown in Figure 1.…”
Section: Description Of Test Objectsmentioning
confidence: 99%
See 2 more Smart Citations
“…Obecnie obowiązujące wymagania [1, 3], w zakresie analizowanych w trakcie badań parametrów początkowych, zestawiono w tabeli 1. Weryfikacja wszystkich wymagań zawartych w rozporządzeniach [1, 3, 4] jest długotrwała i czasochłonna, tak więc zwykle ogranicza się tylko do oceny parametrów początkowych [9,10,11,12,13,14,15]…”
Section: Wstępunclassified