2008
DOI: 10.1080/00032710802238077
|View full text |Cite
|
Sign up to set email alerts
|

Barium(II)-PVC Membrane Sensor Based on 4-4′-Methylenediantipyrine as a Neutral Carrier

Abstract: A highly selective and sensitive poly(vinyl chloride) membrane electrode, using 4-4 0 -Methylenediantipyrine as an ionophore, has been prepared and examined as a Ba 2þ -selective electrode. The influence of the anion excluder (sodium tetraphenyl borate, NaTPB) and the effect of the plasticizers dibutyl phthalate (DBP), nitrobenzene (NB), and benzyl acetate (BA) were studied. The best performance was obtained with the sensor having a membrane composition (w=w) of (MAP, 2.0%), (PVC, 30%), (NB, 66%), (NaTPB, 2.0%… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 49 publications
(15 citation statements)
references
References 49 publications
(45 reference statements)
0
15
0
Order By: Relevance
“…In line with the information of this Table, electrodes reported in the literature by other researchers. [14][15][16][17][18] From the data given in Table 3, the proposed sensor in terms of not only response time, but also selectivity is superior to the previously reported Ho 3+ ion-selective membrane electrode.…”
Section: Selectivity Of the Sensormentioning
confidence: 69%
See 1 more Smart Citation
“…In line with the information of this Table, electrodes reported in the literature by other researchers. [14][15][16][17][18] From the data given in Table 3, the proposed sensor in terms of not only response time, but also selectivity is superior to the previously reported Ho 3+ ion-selective membrane electrode.…”
Section: Selectivity Of the Sensormentioning
confidence: 69%
“…12 There are some reports on the literature for selective determination of holmium ion by potentiometric electrodes. [13][14][15][16][17][18] In this work, selectivity of N- (Figure 1), which is a thio-Schiff's base was conductometrically studied in acetonitrile. Since TPA showed a selective behavior toward holmium ion, it was applied in construction of a Ho(III) selective PVC membrane sensor.…”
Section: Introductionmentioning
confidence: 99%
“…Then A Pyrex tube (5-mm o.d.) was dipped into the oily mixture for~10 s, to achieve a transparent membrane of 0.3 mm in thickness at the tip [28][29][30][31][32][33][34][35][36][37][38][39][40][41]. The tube were then kept at room temperature for 24 h and filled with an internal solution (1.0 × 10 −3 mol L −1 SmCl 3 ), and finally conditioned for 36 h by soaking in a 1.0 × 10 −2 mol L −1 SmCl 3 solution.…”
Section: Electrode Preparationmentioning
confidence: 99%
“…However very few Fe(III)-selective sensors which offer simplicity, rapidity and reliability as an analytical tool have been reported [8][9][10]. Recently, several highly selective and sensitive PVC-membrane ion selective electrodes (ISEs) for various metal ions have been reported [11][12][13][14][15]. In this study, we were also motivated to investigate the fabrication and characterization of a new ISE based on (DEDIO) (Figure 1) as a suitable ionophore.…”
Section: Introductionmentioning
confidence: 99%