2019
DOI: 10.1016/j.ymssp.2018.06.048
|View full text |Cite
|
Sign up to set email alerts
|

Base-isolated structure equipped with tuned liquid column damper: An experimental study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
17
0
2

Year Published

2019
2019
2021
2021

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 48 publications
(19 citation statements)
references
References 18 publications
0
17
0
2
Order By: Relevance
“…"Passive control devices are systems which do not require any external power source, imparting forces that are developed in response to the motion of the structure" [14]. Active control devices "rely on a control algorithm" [15] and thus require an external power source unless the power required to run the control algorithm can be generated by the damper itself. This idea of generating power from the damping action gives rise to the idea of a new breed of smart dampers.…”
Section: Smart Dampersmentioning
confidence: 99%
“…"Passive control devices are systems which do not require any external power source, imparting forces that are developed in response to the motion of the structure" [14]. Active control devices "rely on a control algorithm" [15] and thus require an external power source unless the power required to run the control algorithm can be generated by the damper itself. This idea of generating power from the damping action gives rise to the idea of a new breed of smart dampers.…”
Section: Smart Dampersmentioning
confidence: 99%
“…Los resultados muestran que, para una excitación de ancho de banda amplio, el ACLS se sintoniza con la segunda frecuencia lineal equivalente, y para una excitación de ancho de banda angosto, se sintoniza con la frecuencia predominante del input. Furtmüller et al (2019) analizan ACLS, como un dispositivo de protección sísmica para el control de una Espinoza, G., Quinteros, C., Gajardo, K., Suazo, A. y Quijada, S. (2021). Eficiencia de un amortiguador de columna de líquido sintonizado considerando una excitación sísmica de bajo contenido de frecuencias e incertidumbre.…”
Section: Introductionunclassified
“…Because, unlike traditional TMDs, the equations governing the TLCD controlled systems response is nonlinear and the definition of the optimal TLCD parameters is time‐consuming in a predesign phase, 12,14 many studies have introduced some formulations to choose the optimal parameters of TLCD in a direct way and some experimental tests have been conducted to prove the reliability of these procedures 15 . Furthermore, the effectiveness of TLCDs in reducing the base displacement demand has been experimentally assessed in Furtmüller et al 16 by small‐scale tests on isolated structural models.…”
Section: Introductionmentioning
confidence: 99%